arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1508.03070astro-ph.IM
收藏

James Webb Space Telescope,VI的中红外仪器:中分辨率光谱仪

The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The Medium Resolution Spectrometer

Martyn Wells, J. -W. Pel, Alistair Glasse, G. S. Wright, Gabby Aitink-Kroes, Ruyman Azzollini, Steven Beard, B. R. Brandl, Angus Gallie, V. C. Geers, A. M. Glau… 展开作者

Martyn Wells, J. -W. Pel, Alistair Glasse, G. S. Wright, Gabby Aitink-Kroes, Ruyman Azzollini, Steven Beard, B. R. Brandl, Angus Gallie, V. C. Geers, A. M. Glauser, Peter Hastings, Th. Henning, Rieks Jager, K. Justtanont, Bob Kruizinga, Fred Lahuis, David Lee, I. Martinez-Delgado, J. R. Martinez-Galarza, M. Meijers, Jane E. Morrison, Friedrich Mueller, Thodori Nakos, Brian O'Sullivan, Ad Oudenhuysen, P. Parr-Burman, Evert Pauwels, R. -R. Rohloff, Eva Schmalzl, Jon Sykes, M. P. Thelen, E. F. van Dishoeck, Bart Vandenbussche, Lars B. Venema, Huib Visser, L. B. F. M. Waters, David Wright

摘要:

我们描述了JWST-MIRI仪器的中分辨率光谱仪(MRS)的设计和性能。MRS在紧凑的光机布局中集成了四个同轴光谱通道,可在高达7.7 X 7.7弧秒的视场范围内生成光谱图像,光谱分辨率范围为1,300至3,700。每个通道包括一个全反射积分场单元(IFU):一个“图像切片器”,重新格式化输入场,以呈现给光栅光谱仪。两个1024 X 1024焦平面阵列记录输出光谱图像,其瞬时光谱覆盖范围约为每个通道全波长范围的三分之一。整个5到28.5微米的光谱是通过使用光栅和通带确定过滤器进行三次曝光获得的,这些过滤器是使用两个三位置机构选择的。根据对中红外成像研究所飞行模型的测试,介绍了预期的在轨光学性能,包括光谱和空间覆盖范围及分辨率。重建图像的点扩散函数被证明是衍射限制和光传输被证明是符合设计预期。

英文摘要:

We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral resolving powers ranging from 1,300 to 3,700. Each channel includes an all-reflective integral field unit (IFU): an 'image slicer' that reformats the input field for presentation to a grating spectrometer. Two 1024 X 1024 focal plane arrays record the output spectral images with an instantaneous spectral coverage of approximately one third of the full wavelength range of each channel. The full 5 to 28.5 micron spectrum is then obtained by making three exposures using gratings and pass-band-determining filters that are selected using just two three-position mechanisms. The expected on-orbit optical performance is presented, based on testing of the MIRI Flight Model and including spectral and spatial coverage and resolution. The point spread function of the reconstructed images is shown to be diffraction limited and the optical transmission is shown to be consistent with the design expectations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑