具有0.2ppm不确定度的量化电流源的验证
Validation of a quantized-current source with 0.2 ppm uncertainty
摘要:
我们报告的高精度测量的量子化电流,来源于一个可调势垒单电子泵的频率$f$高达$1$ GHz。测量是用一种新的皮安计仪器进行的,可追溯到约瑟夫森和量子霍尔效应。在$f=545$ MHz下根据$I=ef$用$e$进行电流量化,确认了元电荷,总相对不确定度为0.2 ppm,将现有技术水平提高了约5倍。第一次,一个可能的未来量子电流标准的基础上单电子输运的准确性实验验证优于目前SI内的安培的最佳实现。
英文摘要:
We report on high-accuracy measurements of quantized current, sourced by a tunable-barrier single-electron pump at frequencies $f$ up to $1$ GHz. The measurements were performed with a new picoammeter instrument, traceable to the Josephson and quantum Hall effects. Current quantization according to $I=ef$ with $e$ the elementary charge was confirmed at $f=545$ MHz with a total relative uncertainty of 0.2 ppm, improving the state of the art by about a factor of 5. For the first time, the accuracy of a possible future quantum current standard based on single-electron transport was experimentally validated to be better than the best realization of the ampere within the present SI.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。