起动射流中的标量耗散率测量
Scalar dissipation rate measurements in a starting jet
摘要:
利用平面激光诱导荧光法测量了脉冲启动气体射流中的标量耗散率。测量结果在空间上具有很好的分辨率。用维纳滤波器处理了实验噪声对实验的恶化作用,该滤波器适用于这种大尺度非均匀流。标量耗散率的精度在$20\%$范围内,这是由滤波误差的显式计算确定的。滤波后剩余的字段进行了详细分析,其统计特性表明,这些类似于白噪声的一个很好的近似。修正的水平是最小的标量场,但它的顺序为$40\%$的标量耗散率。使用建模的光谱和测量的空间分辨率的过滤操作的检查表明,维纳滤波器产生的标量耗散率$\sim30\%$的估计误差,泰勒尺度雷诺数高达1000。这种建模的影响进行了讨论,相对于常见的实验情况,并指出相对的优点,提高空间分辨率相比,在信噪比的改善。
英文摘要:
Measurements of the scalar dissipation rate are performed in an impulsively started gas jet, using planar laser induced fluorescence. The measurements are well resolved spatially. The deteriorating effect of experimental noise on this experiment is treated with a Wiener filter, which is shown to be applicable to this large-scale inhomogeneous flow. The accuracy of the scalar dissipation rate is within $20\%$, as determined from an explicit calculation of the filtering errors. The residual fields that remain after the filtering are analysed in detail and their statistical properties show that these resemble white noise to a good approximation. The level of corrections is minimal for the scalar field but it is of the order of $40\%$ for the scalar dissipation rate. An examination of the filtering operation using modeled spectra and the measured spatial resolution shows that the Wiener filter produces errors in the estimate of the scalar dissipation rate $\sim30\%$, for Taylor-scale Reynolds number up to 1000. The implications of this modelling are discussed with respect to common experimental situations and point out the relative merits of improving the spatial resolution as compared to improvements in the signal to noise ratio.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。