三重调制法拉第旋转灵敏装置

A Sensitive Faraday Rotation Setup Using Triple Modulation

Gretchen Phelps, Josh Abney, Mark Broering, Wolfgang Korsch

摘要:

利用极化靶进行散射实验已成为许多主要加速器实验室的普遍做法。稀有气体特别适合于这种应用,因为它们可以使用自旋交换或亚稳态泵浦技术容易地超极化。极化氦-3是一种非常受欢迎的靶,因为它由于其简单的原子核结构而经常用作有效的极化中子。产生和储存极化氦-3的最受欢迎的电池材料是GE-180,一种相对致密的铝硅酸盐玻璃。本文提出了一种法拉第旋转法,采用一种新的三重调制技术,其中SF 57火石玻璃,玻璃和空气的费尔德常数的测量进行了测试。所获得的灵敏度表明,这种技术可以在未来的细胞壁表征和厚度测量中实现。我们还讨论了GE-180玻璃在632 nm、773 nm、1500 nm和1547 nm四个波长值下的费尔德常数的首次提取,由此观察到预期的1/λ^{2}依赖性。

英文摘要:

The utilization of polarized targets in scattering experiments has become a common practice in many major accelerator laboratories. Noble gases are especially suitable for such applications, since they can be easily hyper-polarized using spin exchange or metastable pumping techniques. Polarized helium-3 is a very popular target because it often serves as an effective polarized neutron due to its simple nuclear structure. A favorite cell material to generate and store polarized helium-3 is GE-180, a relatively dense aluminosilicate glass. In this paper, we present a Faraday rotation method, using a new triple modulation technique, where the measurement of the Verdet constants of SF57 flint glass, pyrex glass, and air were tested. The sensitivity obtained shows that this technique may be implemented in future cell wall characterization and thickness measurements. We also discuss the first ever extraction of the Verdet constant of GE-180 glass for four wavelength values of 632 nm, 773 nm, 1500 nm, and 1547 nm, whereupon the expected 1/λ^{2} dependence was observed.