关于Ap星磁场测量的一致性:从FORS1档案中得到的教训
On the consistency of magnetic field measurements of Ap stars: lessons learned from the FORS1 archive
摘要:
上下文FORS 1分光偏振观测的ESO档案可用于创建磁场测量的均匀数据库。然而,迄今为止,还没有对FORS实地测量结果与其他仪器测量结果进行系统的比较。目标。我们利用FORS存档的圆分光偏振测量数据,以一般的方式检查如何可靠和准确的现场检测与FORS获得。方法.我们研究了Ap和Bp星的观测结果,因为FORS 1档案中几乎所有明确的磁场探测都是在这类恒星中。我们评估的整体质量的FORS 1磁数据的一致性,检查从以前的测量与其他仪器获得的字段检测,我们看看内部一致性的模式。结果FORS 1的磁性测量结果与其他仪器的测量结果完全一致,数据的内部一致性非常好。然而,重要的是要认识到,每一个选择的棱镜和波长窗口构成了一个独特的仪器测量系统,并在不同的仪器系统,同时现场测量可能会产生不同的场强值高达20%,或更多。此外,我们发现,使用氢线的场测量仅产生有意义地反映场强度的结果,这些场强度是由有效温度高于约9000 K的恒星的氢线专门采样的。结论.总体上讲,FORS 1对Ap和Bp星的磁场测量具有很好的质量、准确度和精密度,FORS 1提供了一个非常有用的例子,为其他低分辨率卡塞格伦分光偏振计的野外测量提供了宝贵的经验。
英文摘要:
CONTEXT. The ESO archive of FORS1 spectropolarimetric observations may be used to create a homogeneous database of magnetic field measurements. However, no systematic comparison of FORS field measurements to those obtained with other instruments has been undertaken so far. AIMS. We exploit the FORS archive of circular spectropolarimetric data to examine in a general way how reliable and accurate field detections obtained with FORS are. METHODS. We examine the observations of Ap and Bp stars, on the grounds that almost all of the unambiguous detections of magnetic fields in the FORS1 archive are in these kinds of stars. We assess the overall quality of the FORS1 magnetic data by examining the consistency of field detections with what is known from previous measurements obtained with other instruments, and we look at patterns of internal consistency. RESULTS. FORS1 magnetic measurements are fully consistent with those made with other instruments, and the internal consistency of the data is excellent. However, it is important to recognise that each choice of grism and wavelength window constitutes a distinct instrumental measuring system, and that simultaneous field measurements in different instrumental systems may produce field strength values that differ up to 20 %, or more. Furthermore, we found that field measurements using hydrogen lines only yield results that meaningfully reflect the field strength as sampled specifically by lines of hydrogen for stars with effective temperatures above about 9000 K. CONCLUSIONS. In general the magnetic field measurements of Ap and Bp stars obtained with FORS1 are of excellent quality, accuracy and precision, and FORS1 provides an extremely useful example that offers valuable lessons for field measurements with other low- resolution Cassegrain spectropolarimeters.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。