Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration, R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink… 展开作者
SuperCDMS Collaboration, R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban, S. Fallows, E. Figueroa-Feliciano, M. Fritts, G. L. Godfrey, S. R. Golwala, M. Graham, J. Hall, H. R. Harris, S. A. Hertel, T. Hofer, D. Holmgren, L. Hsu, M. E. Huber, A. Jastram, O. Kamaev, B. Kara, M. H. Kelsey, A. Kennedy, M. Kiveni, K. Koch, A. Leder, B. Loer, E. Lopez Asamar, R. Mahapatra, V. Mandic, C. Martinez, K. A. McCarthy, N. Mirabolfathi, R. A. Moffatt, D. C. Moore, R. H. Nelson, S. M. Oser, K. Page, W. A. Page, R. Partridge, M. Pepin, A. Phipps, K. Prasad, M. Pyle, H. Qiu, W. Rau, P. Redl, A. Reisetter, Y. Ricci, H. E. Rogers, T. Saab, B. Sadoulet, J. Sander, K. Schneck, R. W. Schnee, S. Scorza, B. Serfass, B. Shank, D. Speller, S. Upadhyayula, A. N. Villano, B. Welliver, D. H. Wright, S. Yellin, J. J. Yen, B. A. Young, J. Zhang
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
低温暗物质搜索实验(CDMS)采用低温Ge和Si探测器通过目标核的弹性散射来探测WIMP。最后一次分析中,锗暴露量为397.8千克-天,没有观测到任何候选事件,因此,当WIMP质量为60 GeV时,与自旋无关的WIMP-核子截面的上限为6.6 x 10 ^{-44} cm ^2(如果包括之前的CDMS Soudan数据,则为4.6 x 10^{-44} cm ^2)。将讨论当前分析的表面事件抑制能力的改进,其中锗暴露比上次分析中使用的暴露大2.5倍。为了将灵敏度提高到超过1 x 10^{-44} cm ^2的基准,研制了新的1英寸厚的探测器。由六个这种探测器组成的第一个塔已成功地安装在苏丹场址。这些探测器将用于15 kg的SuperCDMS级,预期对自旋无关的WIMP-核子弹性散射截面的灵敏度为5 x 10^{-45} cm ^2。此外,CDMS协作组已经开始寻找非WIMP暗物质粒子的特征,这可能解释DAMA观测到的年度调制特征。
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS和EDELWEISS的合作结合了他们使用低温锗探测器直接搜索暗物质的结果。总数据集代表614 kg.d当量接触。在实验之间交换数据之前,选择了一种简单的组合方法。结果解释的限制自旋无关的WIMP核子截面。对于质量为90 GeV/c^2的WIMP,这种分析是最灵敏的,在90% CL下排除了3.3 x 10^{-44} cm ^2的截面。在更高的WIMP质量下,这种组合使单个极限提高了1.6倍,高于700 GeV/c^2。结合数据的替代方法为WIMP质量的某些范围提供了更强的约束,而为其他范围提供了更弱的约束。
Projected sensitivity to sub-GeV dark matter of next-generation semiconductor detectors
我们计算的投影灵敏度暗物质(DM)粒子在未来的直接探测实验使用锗和硅半导体目标的亚GeV质量范围。我们使用似然比作为检验统计量,Monte Carlo模拟和背景模型,我们从最近的实验数据中提取的DM-电子相互作用的暗光子模型内执行此计算。我们提出了我们的研究结果中所需的DM-电子散射截面值拒绝的背景只有假设,有利于背景加DM信号假设与统计学意义,$\mathcal{Z}$,对应于3或5个标准差。我们还测试了我们的结论的稳定性下的天体物理参数的变化,在银河系中的DM的本地空间和速度分布。在最好的情况下,当具有$50$ kg-年曝光量的高压锗检测器和具有$1$ kg-年曝光量和$1\times10^{-7}$计数/像素/天暗电流率的CCD硅检测器同时报告DM信号时,我们发现与$\mathcal{Z}=3$相容的最小截面值对于接触相互作用,($\mathcal{Z}=5$)约为$8\times10^{-42}$ cm $^2$($1\times10^{-41}$ cm $^2$),对于长程相互作用,约为$4\times10^{-41}$ cm $^2$($7\times10^{-41}$ cm $^2$)。我们的敏感性研究扩展和完善以前的作品在背景模型,统计方法和治疗的基础天体物理学的不确定性。