arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1409.4663astro-ph.IM
收藏

Local Group星团的全色高分辨光谱巡天- I. VLT/X-shooter UVB和VIS组的一般数据简化程序

The Panchromatic High-Resolution Spectroscopic Survey of Local Group Star Clusters - I. General Data Reduction Procedures for the VLT/X-shooter UVB and VIS arm

Frederik Schönebeck, Thomas H. Puzia, Anna Pasquali, Eva K. Grebel, Markus Kissler-Patig, Harald Kuntschner, Mariya Lyubenova, Sibilla Perina

摘要:

我们的数据集包含29个球状星团在麦哲伦云和银河系的光谱观测与VLT/X-shooter。在这里,我们提出了详细的VLT/X-shooter UVB和VIS臂的数据简化程序。这些不限于我们的特定数据集,但通常适用于不同类型的X-shooter数据,而不受天文目标的限制。ESO的X-shooter流水线(v1.5.0)在波长校准和相关的整流过程中表现良好且可靠,但我们发现了减少级联中的几个弱点,这些弱点可以通过额外的校准步骤来解决,例如坏像素插值,平坦场化和狭缝照明校正。此外,仪器PSF解析建模和用于重建在狭缝过境通量损失和最佳提取点源。分光光度标准星的定期观测使我们能够检测仪器的变化,如果需要可靠的绝对通量校准,需要了解这一点。一个级联的额外的自定义校准步骤,允许一个绝对通量校准不确定性小于百分之十,在几乎每一个观测设置提供的信噪比是足够高的。最佳提取通常将信噪比增加1.5倍,同时校正所产生的通量损失。波长校准被发现是准确的不确定性水平约0.02埃。我们发现,大多数的X-射手系统可以可靠地建模和校正。这提供了比较不同夜晚和不同望远镜指向和仪器设置的观测结果的可能性,从而促进了对大型数据集的可靠统计分析。

英文摘要:

Our dataset contains spectroscopic observations of 29 globular clusters in the Magellanic Clouds and the Milky Way performed with VLT/X-shooter. Here we present detailed data reduction procedures for the VLT/X-shooter UVB and VIS arm. These are not restricted to our particular dataset, but are generally applicable to different kinds of X-shooter data without major limitation on the astronomical object of interest. ESO's X-shooter pipeline (v1.5.0) performs well and reliably for the wavelength calibration and the associated rectification procedure, yet we find several weaknesses in the reduction cascade that are addressed with additional calibration steps, such as bad pixel interpolation, flat fielding, and slit illumination corrections. Furthermore, the instrumental PSF is analytically modeled and used to reconstruct flux losses at slit transit and for optimally extracting point sources. Regular observations of spectrophotometric standard stars allow us to detect instrumental variability, which needs to be understood if a reliable absolute flux calibration is desired. A cascade of additional custom calibration steps is presented that allows for an absolute flux calibration uncertainty of less than ten percent under virtually every observational setup provided that the signal-to-noise ratio is sufficiently high. The optimal extraction increases the signal-to-noise ratio typically by a factor of 1.5, while simultaneously correcting for resulting flux losses. The wavelength calibration is found to be accurate to an uncertainty level of approximately 0.02 Angstrom. We find that most of the X-shooter systematics can be reliably modeled and corrected for. This offers the possibility of comparing observations on different nights and with different telescope pointings and instrumental setups, thereby facilitating a robust statistical analysis of large datasets.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑