用于测试基础物理学的UVES大型计划--III。3台望远镜对精细结构常数的限制
The UVES Large Program for testing fundamental physics - III. Constraints on the fine-structure constant from 3 telescopes
摘要:
类星体光谱的大量统计样本先前已经表明精细结构常数$α$可能存在宇宙学上的变化。一个更小的样本,更高的信噪比光谱,专门校准,将允许详细测试这一证据。为此,我们观察赤道类星体HS 1549 $+$ 1919年与三个望远镜:甚大望远镜,凯克,并首次在这样的分析,斯巴鲁。通过直接将这些光谱相互比较,并通过使用小行星和碘电池测试对它们进行"超校准",我们检测并消除了类星体光谱波长尺度的长距离扭曲,这些扭曲会在我们的$α$测量中造成显着的系统误差。对于每个望远镜,我们测量的相对偏差$α$从目前的实验室值,$Δα/α$,在3个吸收系统的红移$z_{\mathrm{abs}}=1.143$,1.342,和1.802。在2-$σ$水平上,$Δα/α$的9次测量值均为零,1-$σ$统计(系统)不确定度为5.6 - 24(1.8 - 7.0)ppm。它们在1-$σ$水平上也彼此一致,使我们能够为每个望远镜形成一个组合值,最后,为这条视线形成一个单一值:$Δα/α=-5.4 \pm 3.3_{\mathrm{stat}} \pm 1.5_{\mathrm{sys}}$ ppm,与零和之前的大样本一致。我们还对测量$Δα/α=-0.6 \pm 1.9_{\mathrm{stat}} \pm 0.9_{\mathrm{sys}}$ ppm的所有大型项目结果进行平均。我们的研究结果表明,在3 ppm的水平提供超校准技术和直接比较光谱从不同的望远镜的鲁棒性和可靠性。
英文摘要:
Large statistical samples of quasar spectra have previously indicated possible cosmological variations in the fine-structure constant, $α$. A smaller sample of higher signal-to-noise ratio spectra, with dedicated calibration, would allow a detailed test of this evidence. Towards that end, we observed equatorial quasar HS 1549$+$1919 with three telescopes: the Very Large Telescope, Keck and, for the first time in such analyses, Subaru. By directly comparing these spectra to each other, and by `supercalibrating' them using asteroid and iodine-cell tests, we detected and removed long-range distortions of the quasar spectra's wavelength scales which would have caused significant systematic errors in our $α$ measurements. For each telescope we measure the relative deviation in $α$ from the current laboratory value, $Δα/α$, in 3 absorption systems at redshifts $z_{\mathrm{abs}}=1.143$, 1.342, and 1.802. The nine measurements of $Δα/α$ are all consistent with zero at the 2-$σ$ level, with 1-$σ$ statistical (systematic) uncertainties 5.6--24 (1.8--7.0) parts per million (ppm). They are also consistent with each other at the 1-$σ$ level, allowing us to form a combined value for each telescope and, finally, a single value for this line of sight: $Δα/α=-5.4 \pm 3.3_{\mathrm{stat}} \pm 1.5_{\mathrm{sys}}$ ppm, consistent with both zero and previous, large samples. We also average all Large Programme results measuring $Δα/α=-0.6 \pm 1.9_{\mathrm{stat}} \pm 0.9_{\mathrm{sys}}$ ppm. Our results demonstrate the robustness and reliability at the 3 ppm level afforded by supercalibration techniques and direct comparison of spectra from different telescopes.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。