利用法布里-珀罗波长校准器在多普勒实验中达到cm/s精度的laser锁概念
A laser-lock concept to reach cm/s-precision in Doppler experiments with Fabry-Perot wavelength calibrators
摘要:
最先进的多普勒实验需要精确到cm/s级别的波长校准。低精细度法布里-珀罗干涉仪(FPI)可以提供天文实验所需的非常大的带宽的波长梳,但不可避免的光谱漂移是难以控制的。而不是主动控制的FPI腔,我们建议被动稳定的干涉仪和跟踪随时间变化的腔长漂移外部。双精细腔允许在观察期间跟踪漂移。在相对于外部标准的高精细度范围内监测腔长的漂移:将单个窄透射峰锁定到外部腔二极管激光器并与原子频率进行比较。按照标准锁定方案,可以实现亚毫米/秒精度的跟踪。这比目前计划的高精度多普勒实验好几个数量级。它允许宽松的设计,使这种方法特别有趣的是即将到来的多普勒实验的自由。我们还表明,在FPI中使用的大量的干涉模式,使我们能够明确地确定每个FPI传输峰值定义其绝对波长解决方案的干涉模式。在每个谐振与激光器的概念达到的精度,然后由腔的长度,确定从一个锁定的峰值和群速度色散。后者可以在相关频率范围内变化数百米/秒,严重限制了单个峰值位置的准确性。确定绝对峰位置的一种潜在方法是用激光频率梳(LFC)从外部测量每个单独峰的频率。因此,激光锁定FPI的概念可能有助于将LFC的绝对精度应用于天文摄谱仪,而无需在天文台使用LFC。
英文摘要:
State-of-the-art Doppler experiments require wavelength calibration with precision at the cm/s level. A low-finesse Fabry-Perot interferometer (FPI) can provide a wavelength comb with a very large bandwidth as required for astronomical experiments, but unavoidable spectral drifts are difficult to control. Instead of actively controlling the FPI cavity, we propose to passively stabilize the interferometer and track the time-dependent cavity length drift externally. A dual-finesse cavity allows drift tracking during observation. The drift of the cavity length is monitored in the high-finesse range relative to an external standard: a single narrow transmission peak is locked to an external cavity diode laser and compared to an atomic frequency. Following standard locking schemes, tracking at sub-mm/s precision can be achieved. This is several orders of magnitude better than currently planned high-precision Doppler experiments. It allows freedom for relaxed designs rendering this approach particularly interesting for upcoming Doppler experiments. We also show that the large number of interference modes used in an FPI allows us to unambiguously identify the interference mode of each FPI transmission peak defining its absolute wavelength solution. The accuracy reached in each resonance with the laser concept is then defined by the cavity length that is determined from the one locked peak and by the group velocity dispersion. The latter can vary by several 100m/s over the relevant frequency range and severely limits the accuracy of individual peak locations. A potential way to determine the absolute peak positions is to externally measure the frequency of each individual peak with a laser frequency comb (LFC). Thus, the concept of laser-locked FPIs may be useful for applying the absolute accuracy of an LFC to astronomical spectrographs without the need for an LFC at the observatory.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。