研究普朗克星系团计数和宇宙学?Chandra/XMM仪器校准和流体静力学质量偏差
Reconciling Planck cluster counts and cosmology? Chandra/XMM instrumental calibration and hydrostatic mass bias
摘要:
星系团的质量可以从其X射线发射气体$T_{\mathrm{X}}$的温度推断出来。如果假设气体处于流体静力平衡,它们的质量可能被低估,低估量为模拟所建议的$b^{\mathrm{hyd}}\sim(20\pm10)$ %。我们以前已经发现的样品之间的一致性观察到的\textit{Chandra} X射线质量和独立的弱透镜测量。不幸的是,{ \em Chandra}和{ \em XMM-Newton}天文台仪器校准的不确定性意味着它们测量相同气体的不同温度。在本文中,我们将相对仪器偏差转化为质量偏差,并推断\textit{XMM-Newton}质量的$\sim 10^{14}\,\mbox{M}_{\odot}$($> 5\cdot 10^{14} \mbox{M}_{\odot}$)集群是无偏的($\sim 35$ %低)相比,WL群众。对于大规模的集群,\textit{Chandra}的校准可能因此更准确。在低质量端,情况似乎相反。我们观察到的质量偏差增加集群质量,但爱丁顿偏见的存在排除了公司的结论,在这个阶段。然而,系统的\textit{Chandra} - \textit{XMM-Newton}差异是重要的,因为{ \em普朗克}通过Sunyaev-Zeldovich(SZ)效应对大质量星系团的探测是通过{ \em XMM-牛顿}观测校准的。SZ星系团的数目与{ \em Planck}对原始宇宙微波背景辐射(CMB)的宇宙学测量结果不一致。鉴于\textit{Planck}簇质量,如果存在(不太可能)未校正的$\sim 20$ %校准偏倚,则该张力将缓解,但未解决。
英文摘要:
The mass of galaxy clusters can be inferred from the temperature of their X-ray emitting gas, $T_{\mathrm{X}}$. Their masses may be underestimated if it is assumed that the gas is in hydrostatic equilibrium, by an amount $b^{\mathrm{hyd}}\sim(20\pm10)$ % suggested by simulations. We have previously found consistency between a sample of observed \textit{Chandra} X-ray masses and independent weak lensing measurements. Unfortunately, uncertainties in the instrumental calibration of {\em Chandra} and {\em XMM-Newton} observatories mean that they measure different temperatures for the same gas. In this paper, we translate that relative instrumental bias into mass bias, and infer that \textit{XMM-Newton} masses of $\sim 10^{14}\,\mbox{M}_{\odot}$ ($> 5\cdot 10^{14} \mbox{M}_{\odot}$) clusters are unbiased ($\sim 35$ % lower) compared to WL masses. For massive clusters, \textit{Chandra}'s calibration may thus be more accurate. The opposite appears to be true at the low mass end. We observe the mass bias to increase with cluster mass, but presence of Eddington bias precludes firm conclusions at this stage. Nevertheless, the systematic \textit{Chandra} -- \textit{XMM-Newton} difference is important because {\em Planck}'s detections of massive clusters via the Sunyaev-Zeldovich (SZ) effect are calibrated via {\em XMM-Newton} observations. The number of detected SZ clusters are inconsistent with {\em Planck}'s cosmological measurements of the primary Cosmic Microwave Background (CMB). Given the \textit{Planck} cluster masses, if an (unlikely) uncorrected $\sim 20$ % calibration bias existed, this tension would be eased, but not resolved.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。