arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1407.0052astro-ph.IM
收藏

适用于4MOST和Hector的高效且经济实惠的折反射摄谱仪设计

Efficient and affordable catadioptric spectrograph designs for 4MOST and Hector

Will Saunders

摘要:

光谱仪成本已经成为多路复用光纤光谱仪器的限制因素,因为现在需要数千万个分辨率元件(光谱x空间)。折反射(类施密特)设计允许更快的相机,从而降低检测器成本,非球面透镜生产的最新进展使整体光学成本与透射设计竞争。经典的施密特设计遭受由位于光束内的探测器引起的阻塞损失。一种新的折反射设计使探测器靠近摄谱仪的光瞳,因此在很大程度上处于望远镜顶端障碍物的阴影中。吞吐量与最好的透射设计相比具有竞争力,并且在蓝色中要好得多,这通常是最有价值的。该设计还具有更温和的非球面,比经典的施密特更紧凑,并避免了他们的大部分操作困难。

英文摘要:

Spectrograph costs have become the limiting factor in multiplexed fiber-based spectroscopic instruments, because tens of millions of resolution elements (spectral x spatial) are now required. Catadioptric (Schmidt-like) designs allow faster cameras and hence reduced detector costs, and recent advances in aspheric lens production make the overall optics costs competitive with transmissive designs. Classic Schmidt designs suffer from obstruction losses caused by the detector being within the beam. A new catadioptric design puts the detector close to the spectrograph pupil, and hence largely in the shadow of the telescope top-end obstruction. The throughput is competitive with the best transmissive designs, and much better in the Blue, where it is usually most valuable. The design also has milder aspheres and is more compact than classic Schmidts, and avoids most of their operational difficulties.