MLC型TrueBeam电子场的蒙特卡罗模拟
Monte Carlo simulation of MLC-shaped TrueBeam electron fields benchmarked against measurement
摘要:
调制电子放射治疗(MERT)和组合调制光子/电子放射治疗(MPERT)已受到越来越多的研究关注,已显示出减少健康组织低剂量暴露的能力,以及许多治疗部位的可比(如果没有改善的话)目标覆盖率。精确的剂量计算工具是临床治疗计划所必需的,而蒙特卡罗(MC)是电子场模拟的金标准。随着许多诊所更换旧的加速器,需要新机器的MC源模型进行持续开发,但是,瓦里安对TrueBeam的内部原理图保密,电子相空间源尚未提供。TrueBeam电子场与Clinac 21 EX产生的电子场没有实质性差异,因此我们修改了Clinac 21 EX的内部示意图,以模拟TrueBeam电子。BEAMnrc/DOSXYZnrc用于模拟具有MLC形孔的5 × 5和20 × 20 cm $^2$电子场。将次级准直钳口设置为超出MLC外围0.5 cm,并设置为40 x 40 cm $^2$。完整的加速器模型与二极管测量一致,在12和20 MeV时在2%/2 mm内,在6 MeV时在3%/3 mm内。测量的深度和剖面数据的比较显示剂量依赖于钳口位置;模拟能量通量评分刚好高于体模显示,对于小孔径,剂量依赖于钳口位置的变化占主导地位的现场能量通量(不分散的钳口或MLC)在6兆电子伏,而在20兆电子伏剂量依赖性占主导地位的散射分量。我们的模型再现这些钳口位置的依赖性,这是一个资产,因为在调制的电子场传输中,钳口的最佳位置没有共识。模拟和测量之间的良好一致性以及钳口位置的灵活性使我们的模型适用于MERT和MPERT计划。
英文摘要:
Modulated electron radiotherapy (MERT) and combined, modulated photon/electron radiotherapy (MPERT) have received increased research attention, having shown capacity for reduced low dose exposure to healthy tissue and comparable, if not improved, target coverage for a number of treatment sites. Accurate dose calculation tools are necessary for clinical treatment planning, and Monte Carlo (MC) is the gold standard for electron field simulation. With many clinics replacing older accelerators, MC source models of the new machines are needed for continued development, however, Varian has kept internal schematics of the TrueBeam confidential and electron phase-space sources have not been made available. TrueBeam electron fields are not substantially different from those generated by the Clinac 21EX, so we have modified the internal schematics of the Clinac 21EX to simulate TrueBeam electrons. BEAMnrc/DOSXYZnrc were used to simulate 5x5 and 20x20 cm$^2$ electron fields with MLC-shaped apertures. Secondary collimating jaws were set 0.5 cm beyond the MLC periphery and to 40x40 cm$^2$. Complete accelerator models agreed with diode measurement within 2%/2 mm at 12 and 20 MeV, and within 3%/3 mm at 6 MeV. Comparisons of measured depth and profile data showed dose-dependencies on jaw position; simulated energy fluences scored just above the phantom showed that, for small apertures, dose dependencies on jaw position are dominated by changes in the in-field energy fluence (not scattered by jaws or MLC) at 6 MeV, while at 20 MeV dose dependencies are dominated by the scattered component. Our models reproduce these jaw position dependencies, which is an asset as there is no consensus on the optimal position for jaws in modulated electron field delivery. Good agreement between simulation and measurement and flexibility in jaw position make our models appropriate for use in MERT and MPERT planning.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。