我们提出的结果比较的生成和测量的直流在PA范围内,可追溯的最先进的方法在最高的精度。电流是用电容器充电方法产生的,并用PTB开发的新型皮安计的第一个原型进行测量。结果证实了两种方法之间的一致性以及新型皮安计在几微A/A的不确定度水平下的线性。此外,他们揭示了电容器的交流-直流差异,这对电容器充电方法产生电流至关重要。

英文摘要:

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity of the new picoammeter at an uncertainty level of few microA/A. Also, they shed light on the ac-dc difference of capacitors, crucial for current generation with the capacitor charging method.