arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1405.2419q-bio.QMcs.SYeess.SY
收藏

无传感器生理控制用于心力衰竭患者植入式旋转血液泵的现代控制技术

Sensorless Physiological Control of Implantable Rotary Blood Pumps for Heart Failure Patients Using Modern Control Techniques

Mohsen A. Bakouri

AI总结:

本文提出了一种结合无传感器和非侵入式数据测量的新控制策略,用于实现适应性强且鲁棒的IRBP控制器,以应对患者条件变化、模型不确定性和外部干扰。

摘要:

心力衰竭患者的一年生存率较低,心脏移植是唯一可行的长期解决方案,但供体心脏数量有限。植入式旋转血液泵(IRBP)是替代方案,但其连续运行需要复杂的控制器以满足基本生理需求。本文旨在设计、开发并实现结合无传感器和非侵入式数据测量的新型控制策略,以提供适应性强且鲁棒的IRBP控制器。通过动物实验数据开发了无传感器脉动流估计器,并基于此开发了先进的生理控制算法,以自动调节泵速以适应代谢需求的变化。通过之前使用健康猪实际数据开发的集中参数模型评估了所开发控制算法的性能。在参数优化的CVS-IRBP交互模型中,研究了控制器对短期循环变化的即时响应以及对长期变化的自适应特性。仿真结果表明,所提出的控制器在面对模型不确定性、参数变化和外部干扰时表现出相当的鲁棒性。

英文摘要:

Sufferers of heart failure disease have a life expectancy of one year and heart transplantation is usually the only guarantee of survival beyond this period. The number of donor hearts available currently is less than 3,000 per annum worldwide. Apart from the relatively fortunate people who receive donor hearts for transplant, the only alternative for people with HF is the implantation of rotary blood pump (IRBP). In fact, an IRBP with its continuous operation requires a more complex controller to achieve basic physiological requirements. The essential control requirement of an IRBP needs to mimic the way that the heart pumps as much blood to the arterial circulation as it receives from the venous circulation. This research aims to design, develop and implement novel control strategies combining sensorless and non-invasive data measurements to provide an adaptive and fairly robust preload sensitive controller for IRBPs subjected to varying patient conditions, model uncertainties and external disturbances. A sensorless pulastile flow estimator was developed using collected data from animal experiments. Based on this estimator, advanced physiological control algorithms for regulation of an IRBP were developed to automatically adjust the pump speed to cater for changes in the metabolic demand.The performance of the developed control algorithms are assessed using a lumped parameter model of the CVS that was previously developed using actual data from healthy pigs over a wide range of operating conditions. Immediate responses of the controllers to short-term circulatory changes as well as adaptive characteristics of the controllers in response to long-term changes are examined in a parameter-optimised model of CVS - IRBP interactions. Simulation results prove that the proposed controllers are fairly robust against model uncertainties, parameter variations and external disturbances.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑