arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1404.2964math.OCcs.GT
收藏

具有事后补偿的应急约束机组组合

Contingency-Constrained Unit Commitment with Post-Contingency Corrective Recourse

Richard Li-Yang Chen, Neng Fan, Ali Pinar, Jean-Paul Watson

摘要:

我们认为,在发电机组组合问题,在电力系统运行的基石,同时执行N-K-E可靠性标准的成本最小化的问题。该可靠性标准是公知的$N$标准的推广,并且规定在$k$或更少的系统部件失效之后,必须满足总系统需求的至少$(1-e_ j)$部分。我们把这个问题称为权变约束机组组合问题,或CCUC。我们提出了一个混合整数规划制定的CCUC,占传输和发电元件故障。我们提出了新的切割平面算法,避免了需要明确考虑指数数量的突发事件。几个IEEE测试系统和美国西部互连网络的简化模型,这表明我们所提出的方法相对于当前最先进的有效性进行计算研究。

英文摘要:

We consider the problem of minimizing costs in the generation unit commitment problem, a cornerstone in electric power system operations, while enforcing an N-k-e reliability criterion. This reliability criterion is a generalization of the well-known $N$-$k$ criterion, and dictates that at least $(1-e_ j)$ fraction of the total system demand must be met following the failures of $k$ or fewer system components. We refer to this problem as the Contingency-Constrained Unit Commitment problem, or CCUC. We present a mixed-integer programming formulation of the CCUC that accounts for both transmission and generation element failures. We propose novel cutting plane algorithms that avoid the need to explicitly consider an exponential number of contingencies. Computational studies are performed on several IEEE test systems and a simplified model of the Western US interconnection network, which demonstrate the effectiveness of our proposed methods relative to current state-of-the-art.