与非弹性或多电子价带光电发射过程有关的俄歇光电发射符合谱(APECS)的本底测量
Measurement of the background in Auger-photoemission coincidence spectra (APECS) associated with inelastic or multi-electron valence band photoemission processes
摘要:
俄歇光电子符合谱(APECS),其中俄歇谱与芯能级光电子一致地测量,能够将难以观察的低能俄歇峰从大背景中拉出,这主要是由于非弹性散射的价带(VB)光电子。然而,单独的APECS方法不能消除由于价带光电发射过程的背景,其中初始光子能量由两个或更多个电子共享,并且其中一个电子处于芯能级光电发射峰的能量范围内。在这里,我们描述了一种实验方法,以确定这些背景过程的贡献,并应用这种方法的情况下,铜M3 VV俄歇光谱获得符合3 p3/2光电发射峰。一束200 eV的光子入射到Cu(100)样品上,并使用配备有两个柱面镜分析器(CMA)的光谱仪进行一系列符合测量。一个CMA被设置在一系列固定的能量范围之间的核心和VB峰的能量。另一个CMA在与离开表面的电子对应的范围内进行扫描,该范围在0 eV至70 eV之间。然后将测量的光谱集拟合到参数化函数,该参数化函数被外推以确定由于多电子和非弹性VB光电发射过程导致的APECS光谱中的背景。从APECS光谱中减去外推的背景,以获得仅作为俄歇过程的结果发射的电子的光谱。的符合光谱与相同的光谱与背景去除的比较表明,在Cu M3 VV的情况下,由于VB电子的非弹性散射的背景是可以忽略的俄歇峰的区域中,但超过一半的总信号下降的低能量尾部的俄歇峰。
英文摘要:
Auger Photoelectron Coincidence Spectroscopy (APECS), in which the Auger spectra is measured in coincidence with the core level photoelectron, is capable of pulling difficult to observe low energy Auger peaks out of a large background due mostly to inelastically scattered valence band (VB) photoelectrons. However the APECS method alone cannot eliminate the background due to valence band photoemission processes in which the initial photon energy is shared by two or more electrons and one of the electrons is in the energy range of the core level photoemission peak. Here we describe an experimental method to determine the contributions from these background processes and apply this method in the case of Copper M3VV Auger spectrum obtained in coincidence with the 3p3/2 photoemission peak. A beam of 200 eV photons was incident on a Cu(100) sample and a series of coincidence measurements were performed using a spectrometer equipped with two cylindrical mirror analyzers (CMAs). One CMA was set at series of fixed energies that ranged between the energy of the core and the VB peaks. The other CMA was scanned over a range corresponding to electrons leaving the surface between 0eV and 70eV. The set of measured spectra were then fit to a parameterized function which was extrapolated to determine the background in the APECS spectra due to multi-electron and inelastic VB photoemission processes. The extrapolated background was subtracted from the APECS spectrum to obtain the spectrum of electrons emitted solely as the result of the Auger process. A comparison of the coincidence spectrum with the same spectrum with background removed shows that in the case of Cu M3VV the background due to the inelastic scattering of VB electrons is negligible in the region of the Auger peak but is more than half the total signal down in the low energy tail of the Auger peak.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。