arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1403.8115astro-ph.IMphysics.ins-det
收藏

利用纳米级炸药的新型暗物质探测器

New Dark Matter Detector using Nanoscale Explosives

Alejandro Lopez, Andrzej Drukier, Katherine Freese, Cagliyan Kurdak, Gregory Tarle

摘要:

我们提出了纳米炸药作为一种新型的暗物质探测器,并研究了点火性能。当来自星系晕的弱相互作用大质量粒子WIMP从探测器中的原子核弹性散射时,沉积的少量能量可以引发爆炸。为具体起见,本文重点介绍一种称为纳米热矿的双组分炸药,由金属和氧化物紧密相连。当这两种成分相互作用时,它们会发生快速的放热反应--爆炸。作为一个具体的例子,我们考虑嵌入在氧化物中的5 nm半径的金属纳米颗粒。一个细胞包含超过几百万个纳米粒子,大量细胞加起来总共有1公斤的探测器质量。WIMP与纳米颗粒的金属核相互作用,沉积足够的能量以在两层之间的界面处引发反应。当一个纳米颗粒爆炸时,它会引发整个细胞的链式反应。一些可能的铝热剂材料进行了研究。由于探测器的纳米级粒度,可以实现出色的背景抑制:而WIMP将导致单个细胞爆炸,背景将引发多个细胞。如果探测器在室温下工作,我们发现质量超过100 GeV(或超过1 TeV的某些材料)的WIMP可以被探测到;它们沉积了足够的能量($>$ 10 keV)来引起爆炸。当在液氮或液氦温度下低温操作时,纳米爆炸WIMP探测器可以探测低至0.5 keV的能量沉积,使纳米爆炸探测器对非常轻的$<$ 10 GeV WIMP更敏感,优于其他暗物质探测器。

英文摘要:

We present nanoscale explosives as a novel type of dark matter detector and study the ignition properties. When a Weakly Interacting Massive Particle WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the small amount of energy deposited can trigger an explosion. For specificity, this paper focuses on a type of two-component explosive known as a nanothermite, consisting of a metal and an oxide in close proximity. When the two components interact they undergo a rapid exothermic reaction --- an explosion. As a specific example, we consider metal nanoparticles of 5 nm radius embedded in an oxide. One cell contains more than a few million nanoparticles, and a large number of cells adds up to a total of 1 kg detector mass. A WIMP interacts with a metal nucleus of the nanoparticles, depositing enough energy to initiate a reaction at the interface between the two layers. When one nanoparticle explodes it initiates a chain reaction throughout the cell. A number of possible thermite materials are studied. Excellent background rejection can be achieved because of the nanoscale granularity of the detector: whereas a WIMP will cause a single cell to explode, backgrounds will instead set off multiple cells. If the detector operates at room temperature, we find that WIMPs with masses above 100 GeV (or for some materials above 1 TeV) could be detected; they deposit enough energy ($>$10 keV) to cause an explosion. When operating cryogenically at liquid nitrogen or liquid helium temperatures, the nano explosive WIMP detector can detect energy deposits as low as 0.5 keV, making the nano explosive detector more sensitive to very light $<$10 GeV WIMPs, better than other dark matter detectors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑