用于毫开尔文实验的银-环氧微波滤波器和热化器
Silver-Epoxy Microwave Filters and Thermalizers for Millikelvin Experiments
摘要:
我们提出的银环氧树脂滤波器结合了良好的微波衰减与有效的导线热化,适用于低温量子输运实验。在最小化寄生电容后,衰减在~150 MHz以上达到>100 dB,并且当添加电容器时,衰减已经在~30 MHz以上。我们用GaAs量子点测量器件的电子温度,并展示了优异的滤波性能。在改进样品架和增加第二个过滤阶段后,我们在金属库仑阻塞温度计中获得了低至7.5 +/- 0.2 mK的电子温度。
英文摘要:
We present Silver-epoxy filters combining excellent microwave attenuation with efficient wire thermalization, suitable for low temperature quantum transport experiments. Upon minimizing parasitic capacitances, the attenuation reaches >100 dB above ~150 MHz and - when capacitors are added - already above ~30 MHz. We measure the device electron temperature with a GaAs quantum dot and demonstrate excellent filter performance. Upon improving the sample holder and adding a second filtering stage, we obtain electron temperatures as low as 7.5 +/- 0.2 mK in metallic Coulomb blockade thermometers.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。