Thorotrast和体内二氧化钍:大型紧凑源附近组织对α辐射吸收的30年数值模拟

Thorotrast and in vivo thorium dioxide: numerical simulation of 30 years of alpha radiation absorption by the tissues near a large compact source

Andrea Bianconi

摘要:

背景资料:名为Thorotrast的轻微放射性造影剂的流行病学显示,在注射和相关病理的发展之间存在非常长的潜伏期。这是放射性内部污染物造成的更普遍问题的一个例子,其影响在短期内并不显著,但在长期内会变得引人注目。仍有待探讨的一点是组织对辐射的局部吸收的波动(在空间和时间上)。研究方法:已经开发了一种蒙特卡罗模拟代码,以研究30年期间内,放置在离模型源0-100微米距离处的微米大小的组织部分对α辐射的每日吸收,该模型源近似于肝脏或脾脏中的尺寸大于或等于20微米的致密二氧化钍源。考虑到生物耗尽的子核的钍系列。初始条件假定天然钍经过化学提纯。结果:大部分吸收剂量集中在邻近源边界的25微米厚的组织层中。其中具有1立方微米体积的目标区域在一天内或在更短的时间段内被3-5个α粒子击中的波动在邻近源边界的1-10微米厚的组织层中是相关的,其中它们的频率大于泊松定律预测。

英文摘要:

Background: The epidemiology of the slightly radioactive contrast agent named Thorotrast presents a very long latency period between the injection and the development of the related pathologies. It is an example of the more general problem posed by a radioactive internal contaminant whose effects are not noteworthy in the short term but become dramatic in the long period. A point that is still to be explored is fluctuations (in space and time) in the localized absorption of radiation by the tissues. Methods: A Monte Carlo simulation code has been developed to study over a 30 year period the daily absorption of alpha radiation by micrometer sized portions of tissue placed at a distance of 0-100 micrometers from a model source, that approximates a compact thorium dioxide source in liver or spleen whose size is larger or equal to 20 micrometers. The biological depletion of the daughter nuclei of the thorium series is taken into account. The initial condition assumes chemically purified natural thorium. Results: Most of the absorbed dose is concentrated in a 25 micrometer thick layer of tissue, adjacent to the source boundary. Fluctuations where a target region with a volume of 1 cube micrometer is hit by 3-5 alpha particles in a day or in a shorter period of time are relevant in a 1-10 micrometer thick layer of tissue adjacent to the source boundary, where their frequency is larger than the Poisson law prediction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑