arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1401.6693physics.ins-dethep-ex
收藏

厘米级液氩电击穿实验研究

Experimental study of electric breakdowns in liquid argon at centimeter scale

A. Blatter, A. Ereditato, C. -C. Hsu, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, M. Schenk, T. Strauss, M. S. Weber, M. Zeller

摘要:

本文介绍了在液态氩沸点附近和阴阳极间距为0.1 ~ 40 mm范围内,用球形阴极和平面阳极测量液态氩的介电强度的结果。我们表明,在这样的距离所施加的电场发生击穿低至40 kV/cm。从55 kV的电压开始,在300 mm的长度上观察到跨越高压馈通件的肋状电介质的闪络。这些结果为液氩时间投影室等离子体探测器的防击穿设计提供了参考。

英文摘要:

In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑