iDataCool:具有热水冷却和能量再利用功能的HPC

iDataCool: HPC with Hot-Water Cooling and Energy Reuse

Nils Meyer, Manfred Ries, Stefan Solbrig, Tilo Wettig

摘要:

iDataCool是由雷根斯堡大学和IBM Böblingen研发实验室联合开发的HPC架构。它基于IBM的iDataBase平台,其空气冷却解决方案被定制的水冷解决方案所取代,允许冷却水温度为70 C/158 F。该系统连接到InvenSor的吸附式制冷机,可在这些温度下高效运行。因此,HPC上消耗的大部分能量可以以冷冻水的形式回收,然后可以用于冷却计算中心的其他部分。我们描述了iDataCool的架构,并提出了基准的冷却性能和能源(重用)效率。

英文摘要:

iDataCool is an HPC architecture jointly developed by the University of Regensburg and the IBM Research and Development Lab Böblingen. It is based on IBM's iDataPlex platform, whose air-cooling solution was replaced by a custom water-cooling solution that allows for cooling water temperatures of 70C/158F. The system is coupled to an adsorption chiller by InvenSor that operates efficiently at these temperatures. Thus a significant portion of the energy spent on HPC can be recovered in the form of chilled water, which can then be used to cool other parts of the computing center. We describe the architecture of iDataCool and present benchmarks of the cooling performance and the energy (reuse) efficiency.