XFEL超导腔体测试用垂直探头的设计参数及调试
Design Parameters and Commissioning of Vertical Inserts Used for Testing the XFEL Superconducting Cavities
摘要:
欧洲XFEL是一个新的研究设施,目前正在德国汉堡地区的DESY建设中。从2015年起,它将产生极强的X射线闪光,供世界各地的研究人员使用。超导XFEL直线加速器由100个加速器模块组成,内部有800多个RF腔。加速器模块、超导磁体和腔体将在加速器模块测试设施(AMTF)中进行测试。本文概述了AMTF大厅两台低温恒温器(XATC)中垂直插入件的设计参数和调试情况。插入件用作4个九室腔的固定器。这使得可以并行地将4个腔冷却到2K,从而减少测试时间。将对每个腔体单独进行以下射频测量(选择作为质量检查)。之后,腔体将再次预热,并将被发送到加速器模块组件。
英文摘要:
The European XFEL is a new research facility currently under construction at DESY in the Hamburg area in Germany. From 2015 on, it will generate extremely intense X-ray flashes that will be used by researchers from all over the world. The superconducting XFEL linear accelerator consists of 100 accelerator modules with more than 800 RF-cavities inside. The accelerator modules, superconducting magnets and cavities will be tested in the accelerator module test facility (AMTF). This paper gives an overview of the design parameters and the commissioning of the vertical insert, used in two cryostats (XATC) of the AMTF-hall. The Insert serves as a holder for 4 nine-cell cavities. This gives the possibility to cool down 4 cavities to 2K in parallel and, consequently, to reduce the testing time. The following RF measurement, selected as quality check, will be done separately for each cavity. Afterwards the cavities will be warmed up again and will be sent to the accelerator module assembly.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。