arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1305.0951astro-ph.GAastro-ph.CO
收藏

用HI 21 cm吸收-发射光谱仪精确测量HI柱密度

Accurate measurement of the HI column density from HI 21cm absorption-emission spectroscopy

Jayaram N. Chengalur, Nissim Kanekar, Nirupam Roy

摘要:

我们提出了一个详细的研究的HI柱密度的估计,HI 21厘米吸收和HI 21厘米发射光谱的组合的基础上。这个“等温”估计值由$N_{\rm HI,ISO} = 1.823 \times 10^{18} \int \left[ τ_{\rm tot} \times {\rm T_B} \right] / \left[ 1 - e^{-τ_{\rm tot}} \right] {\rm dV}$给出,其中$τ_{\rm tot}$是沿视线的总HI 21 cm光学深度,${\rm T_B}$是测量的亮度温度。我们已经使用了蒙特卡罗模拟来量化的准确性的等温估计比较派生的$N_{\rm HI,ISO}$与真正的HI柱密度$N_{\rm HI}$。对不同温度相的气体和沿路径的任意位置的大范围视线进行了模拟,发现模拟结果对假设的气体温度分布和沿视线的不同相的位置统计不敏感。真实H{ \sc i}柱密度与等温估计值$N_{\rm HI}/{N_{\rm HI, ISO}}$之比的中值在2的单位因子内,而68.2%置信区间在$\approx 3$的单位因子内,直至高HI柱密度$\le 5 \times 10^{23}$ \,cm $^{-2}$/1 km s $^{-1}$通道和高总光学深度$\le 1000$。因此,等温估计提供了一个显着更好的测量HI柱密度比其他方法,即使在最高列的几个真实值的一个因素内,应该让我们直接探测高HI柱密度气体在银河系中的存在。

英文摘要:

We present a detailed study of an estimator of the HI column density, based on a combination of HI 21cm absorption and HI 21cm emission spectroscopy. This "isothermal" estimate is given by $N_{\rm HI,ISO} = 1.823 \times 10^{18} \int \left[ τ_{\rm tot} \times {\rm T_B} \right] / \left[ 1 - e^{-τ_{\rm tot}} \right] {\rm dV}$, where $τ_{\rm tot}$ is the total HI 21cm optical depth along the sightline and ${\rm T_B}$ is the measured brightness temperature. We have used a Monte Carlo simulation to quantify the accuracy of the isothermal estimate by comparing the derived $N_{\rm HI,ISO}$ with the true HI column density $N_{\rm HI}$. The simulation was carried out for a wide range of sightlines, including gas in different temperature phases and random locations along the path. We find that the results are statistically insensitive to the assumed gas temperature distribution and the positions of different phases along the line of sight. The median value of the ratio of the true H{\sc i} column density to the isothermal estimate, $N_{\rm HI}/{N_{\rm HI, ISO}}$, is within a factor of 2 of unity while the 68.2% confidence intervals are within a factor of $\approx 3$ of unity, out to high HI column densities, $\le 5 \times 10^{23}$\,cm$^{-2}$ per 1 km s$^{-1}$ channel, and high total optical depths, $\le 1000$. The isothermal estimator thus provides a significantly better measure of the HI column density than other methods, within a factor of a few of the true value even at the highest columns, and should allow us to directly probe the existence of high HI column density gas in the Milky Way.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑