arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1303.6768physics.ins-detnucl-ex
收藏

用于{ \sc Gerda}的同位素修饰Ge探测器:从生产到运行

Isotopically modified Ge detectors for {\sc Gerda}: from production to operation

D. Budjáš, M. Agostini, L. Baudis, E. Bellotti, L. Bezrukov, R. Brugnera, C. Cattadori, A. di Vacri, R. Falkenstein, A. Garfagnini, S. Georgi, P. Grabmayr, A. H… 展开作者

D. Budjáš, M. Agostini, L. Baudis, E. Bellotti, L. Bezrukov, R. Brugnera, C. Cattadori, A. di Vacri, R. Falkenstein, A. Garfagnini, S. Georgi, P. Grabmayr, A. Hegai, S. Hemmer, M. Hult, J. Janicskó Csáthy, V. Kornoukhov, B. Lehnert, A. Lubashevskiy, S. Nisi, G. Pivato, S. Schönert, M. Tarka, K. von Sturm

摘要:

\textsc{Gerda}实验通过新颖的脉冲形状鉴别(PSD)技术来搜索无中微子双β($0νβ$ β $) decay of $ ^{76} $Ge using high-purity germanium detectors made of material enriched in $ ^{76} $Ge. For Phase II of the experiment a sensitivity for the half life $ T_{1/2} ^{0ν}\,\,\sim 2 \cdot 10^{26} $ yr is envisioned. Modified Broad Energy Germanium detectors (BEGe) with thick n$ ^+ $ electrodes provide the capability to efficiently identify and reject background events, while keeping a large acceptance for the $ 0νβ $beta$ -衰变信号。生产厚窗口BEGe型探测器的\textsc{Gerda}实验的可行性证明了通过测试所有的生产步骤,从采购的同位素改性锗工作BEGe探测器。对\textsc{Gerda} Phase II原型BEGe探测器的光谱性能和PSD性能进行的全面测试证明,这些探测器的性能与之前按照制造商的标准生产线从天然锗材料生产的探测器的性能相同。此外,从有限量的同位素改性的锗生产BEGe检测器用于优化生产,以最大化总检测器质量产率。这一试验活动的结果为随后生产富锗探测器提供了直接投入。

英文摘要:

The \textsc{Gerda} experiment searches for the neutrinoless double beta ($0νβ$beta$) decay of $^{76}$Ge using high-purity germanium detectors made of material enriched in $^{76}$Ge. For Phase II of the experiment a sensitivity for the half life $T_{1/2}^{0ν}\,\,\sim2\cdot10^{26}$ yr is envisioned. Modified Broad Energy Germanium detectors (BEGe) with thick n$^+$ electrodes provide the capability to efficiently identify and reject background events, while keeping a large acceptance for the $0νβ$beta$-decay signal through novel pulse-shape discrimination (PSD) techniques. The viability of producing thick-window BEGe-type detectors for the \textsc{Gerda} experiment is demonstrated by testing all the production steps from the procurement of isotopically modified germanium up to working BEGe detectors. Comprehensive testing of the spectroscopic as well as PSD performance of the \textsc{Gerda} Phase II prototype BEGe detectors proved that the properties of these detectors are identical to those produced previously from natural germanium material following the standard production line of the manufacturer. Furthermore, the production of BEGe detectors from a limited amount of isotopically modified germanium served to optimize the production, in order to maximize the overall detector mass yield. The results of this test campaign provided direct input for the subsequent production of the enriched germanium detectors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑