一种新的微阵列实验方法以解决实验噪声和探针响应的不确定性

A New Procedure for Microarray Experiments to Account for Experimental Noise and the Uncertainty of Probe Response

Alex E Pozhitkov, Peter A Noble, Jaroslaw Bryk, Diethard Tautz

摘要:

虽然微阵列是生物医学研究中的常规分析工具,但它们仍然会产生经常需要实验确认的噪声输出。许多研究旨在优化探针设计和统计分析来解决这个问题。然而,较少的重点放在控制固有的噪声的实验方法。为了解决这个问题,我们在这里调查一个程序,控制这样的实验方差,并将其与探针性能的评估。使用两个定制阵列来评估该程序:一个基于来自Affytron设计的25聚体探针,另一个基于来自Agilent设计的60聚体探针。为了评估实验方差,将所有探针重复10次。为了评估探针性能,使用靶分子的稀释系列校准探针,并将信号响应拟合至吸收模型。我们发现,信号的显着变化可以通过平均跨探针和删除探针是无响应的控制。因此,使用我们的方法可以获得比传统方法更可靠的信号。我们建议,一旦阵列被正确校准,信号的绝对定量变得直截了当,减轻了对标准化和参考杂交的需要。

英文摘要:

Although microarrays are routine analysis tools in biomedical research, they still yield noisy output that often requires experimental confirmation. Many studies have aimed at optimizing probe design and statistical analysis to tackle this problem. However, less emphasis has been placed on controlling the noise inherent to the experimental approach. To address this problem, we investigate here a procedure that controls for such experimental variance and combine it with an assessment of probe performance. Two custom arrays were used to evaluate the procedure: one based on 25mer probes from an Affymetrix design and the other based on 60mer probes from an Agilent design. To assess experimental variance, all probes were replicated ten times. To assess probe performance, the probes were calibrated using a dilution series of target molecules and the signal response was fitted to an absorption model. We found that significant variance of the signal could be controlled by averaging across probes and removing probes that are nonresponsive. Thus, a more reliable signal could be obtained using our procedure than conventional approaches. We suggest that once an array is properly calibrated, absolute quantification of signals becomes straight forward, alleviating the need for normalization and reference hybridizations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑