MT和溢出校正以及T1-compensated稳态脉冲CEST-MRI的逆Z谱分析-应用于急性卒中的pH-weighted MRI
Inverse Z-spectrum analysis for MT- and spillover-corrected and T1-compensated steady-state pulsed CEST-MRI - application to pH-weighted MRI of acute stroke
摘要:
内源化学交换饱和转移(CEST)效应总是被直接水质子饱和(溢出)和大分子磁化转移(MT)等竞争效应所稀释。这导致在CEST的实际生化对比中的T2和MT穿透效应。因此,寻找校正CEST信号的简单评估算法。采用最近的本征空间理论自旋锁和连续波(cw)CEST有效,我们预测,逆Z-谱是有益的Z-谱本身。在此基础上,我们提出了一个新的溢出和MT校正磁化传递比(MTRRex)产生雷克斯,在旋转框架中的交换依赖的弛豫率。为了验证,在临床场强为3 T的条件下,对不同琼脂浓度溶液中肌酸的胺质子交换进行了实验研究。与脉冲CEST实验的比较标准评估MTRasym相比,我们的方法显示没有T2或MT穿透效应。我们证明,溢出可以得到适当的校正,也可以定量评价pH值和肌酸浓度,这证明MTRRex作为定量CEST-MRI方法。溢出校正是特别感兴趣的临床静态场强和质子共振附近的水峰。这是-OH-CEST效应的情况,如gagCEST或glucoCEST,但也需要高B1的肌酸或谷氨酸的胺交换。虽然,只显示了胺交换,我们建议我们的标准化工作一般为DIACEST,PARACEST在缓慢和快速交换制度不仅作为一个校正,而且定量CEST-MRI。应用于大鼠脑中诱导的急性中风,与传统方法相比,校正的CEST信号显示中风区域和正常组织之间的显著更高的对比度以及更少的B1依赖性。
英文摘要:
Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects such as direct water proton saturation (spillover) and macromolecular magnetization transfer (MT). This leads to T2-and MT-shine-through effects in the actual biochemical contrast of CEST. Therefore, a simple evaluation algorithm which corrects the CEST signal was searched for. By employing a recent eigenspace theory valid for spinlock and continuous wave (cw) CEST we predict that the inverse Z-spectrum is beneficial to Z-spectrum itself. Based on this we propose a new spillover- and MT-corrected magnetization transfer ratio (MTRRex) yielding Rex, the exchange dependent relaxation rate in the rotating frame. For verification, the amine proton exchange of creatine in solutions with different agar concentration was studied experimentally at clinical field strength of 3T. In contrast to the compared standard evaluation for pulsed CEST experiments, MTRasym, our approach shows no T2 or MT shine through effect. We demonstrate that spillover can be corrected properly and also quantitative evaluation of pH and creatine concentration is possible which proves MTRRex as quantitative CEST-MRI method. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for -OH-CEST effects like gagCEST or glucoCEST, but also amine exchange of creatine or glutamate which require high B1. Although, only showed for amine exchange, we propose our normalization to work generally for DIACEST, PARACEST in slow- and fast exchange regime not just as a correction, but also for quantitative CEST-MRI. Applied to acute stroke induced in rat brain, the corrected CEST signal shows significantly higher contrast between stroke area and normal tissue as well as less B1 dependency compared to conventional approaches.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。