arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1302.6070astro-ph.IM
收藏

INTEGRAL/IBIS面罩的飞行中校准

In-flight calibration of the INTEGRAL/IBIS mask

S. Soldi, F. Lebrun, A. Gros, G. Belanger, V. Beckmann, I. Caballero, A. Goldwurm, D. Gotz, F. Mattana, J. A. Zurita Heras, A. Bazzano, P. Ubertini

摘要:

自INTEGRAL离线科学分析(OSA)软件9.0版发布以来,在INTEGRAL/IBIS成像程序中引入了鬼影克星模块,从而将亮光源周围的灵敏度提高了7倍。该模块在去卷积过程中排除了与通过受某些缺陷影响的掩模元件的亮源投影相对应的IBIS/ISGRI检测器像素。这些缺陷很可能与将IBIS面罩固定到其支架上的螺钉和胶水有关。在OSA 9中引入这些主要改进之后,仍然需要二阶校正以进一步去除残余噪声,现在在视场中最亮源的0.2-1%的水平。为了提高我们对IBIS面罩透明度的认识,在2010-2012年期间开展了校准活动。我们在这里提出的这些数据的分析,连同档案观测的螃蟹和天鹅座X-1,使我们能够建立一个复合图像的掩模缺陷,并调查的残留噪声的来源在IBIS/ISGRI图像。由于这项研究,我们能够指出ISGRI分析软件的一个简单修改,可以显着提高图像的质量,其中在视场边缘检测到明亮的光源。此外,被排除在幽灵克星模块的区域的细化被认为是,初步结果表明,进一步测试的改进。最后,本研究指出了进一步的研究方向,以提高ISGRI的灵敏度,如考虑到在掩模模型中的螺钉的厚度或研究建模和实际掩模元件的桥梁之间可能存在的差异。

英文摘要:

Since the release of the INTEGRAL Offline Scientific Analysis (OSA) software version 9.0, the ghost busters module has been introduced in the INTEGRAL/IBIS imaging procedure, leading to an improvement of the sensitivity around bright sources up to a factor of 7. This module excludes in the deconvolution process the IBIS/ISGRI detector pixels corresponding to the projection of a bright source through mask elements affected by some defects. These defects are most likely associated with screws and glue fixing the IBIS mask to its support. Following these major improvements introduced in OSA 9, a second order correction is still required to further remove the residual noise, now at a level of 0.2-1% of the brightest source in the field of view. In order to improve our knowledge of the IBIS mask transparency, a calibration campaign has been carried out during 2010-2012. We present here the analysis of these data, together with archival observations of the Crab and Cyg X-1, that allowed us to build a composite image of the mask defects and to investigate the origin of the residual noise in the IBIS/ISGRI images. Thanks to this study, we were able to point out a simple modification of the ISGRI analysis software that allows to significantly improve the quality of the images in which bright sources are detected at the edge of the field of view. Moreover, a refinement of the area excluded by the ghost busters module is considered, and preliminary results show improvements to be further tested. Finally, this study indicates further directions to be investigated for improving the ISGRI sensitivity, such as taking into account the thickness of the screws in the mask model or studying the possible discrepancy between the modeled and actual mask element bridges.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑