Cross-calibration of Suzaku XIS and XMM-Newton EPIC using clusters of galaxies
摘要:
我们扩展了以前的交叉校准研究的国际天文学联盟的高能校准(IACHEC)XMM-牛顿/EPIC,钱德拉/ACIS和BeppoSAX/MECS X射线仪器与星系团的朱雀/XIS仪器。我们的目的是研究的准确性的能量依赖的有效面积校准的XIS仪器通过比较的光谱温度,通量和拟合残差与朱雀/XIS和XMM-牛顿/EPIC-pn获得相同的集群。所有仪器在2.0 - 7.0 keV硬能带测量的温度在5%以内是一致的。然而,XIS仪器在软0.5 - 2.0 keV频段获得的温度不一致9 - 29%。我们研究了XIS软带中的残差,结果表明,如果精确校准XIS 0有效面积形状,则XIS 1和XIS 3的有效面积被高估,低于1.0 keV(反之亦然)。调整柱密度的XIS污染物在3 - 6弧分提取区域的建模,同时迫使一致的排放模型,在每个仪器为一个给定的集群显着提高了拟合。XIS 1和XIS 3污染物中的氧柱密度必须比当前校准中实现的值增加1 - 2E17 cm ^-2,而分析给出的XIS 0污染物的柱密度与公共校准一致。XIS软带温度与修改的污染物的柱密度得到更好的同意与EPIC-pn仪器的XMM-牛顿,比与那些来自使用Chandra-ACIS仪器的温度。然而,使用Suzaku-XIS获得的硬带通量与使用Chandra-ACIS和EPIC-pn仪器获得的通量的比较证明是不确定的。
英文摘要:
We extend a previous cross-calibration study by the International Astronomical Consortium for High Energy Calibration (IACHEC) on XMM-Newton/EPIC, Chandra/ACIS and BeppoSAX/MECS X-ray instruments with clusters of galaxies to Suzaku/XIS instruments. Our aim is to study the accuracy of the energy-dependent effective area calibration of the XIS instruments by comparison of spectroscopic temperatures, fluxes and fit residuals obtained with Suzaku/XIS and XMM-Newton/EPIC-pn for the same cluster. The temperatures measured in the hard 2.0-7.0 keV energy band with all instruments are consistent within 5 %. However, temperatures obtained with the XIS instruments in the soft 0.5-2.0 keV band disagree by 9-29 %. We investigated residuals in the XIS soft band, which showed that if XIS0 effective area shape is accurately calibrated, the effective areas of XIS1 and XIS3 are overestimated below 1.0 keV (or vice versa). Adjustments to the modelling of the column density of the XIS contaminant in the 3-6 arcmin extraction region while forcing consistent emission models in each instrument for a given cluster significantly improved the fits. The oxygen column density in XIS1 and XIS3 contaminant must be increased by 1-2E17 cm^-2 in comparison to the values implemented in the current calibration, while the column density of the XIS0 contaminant given by the analysis is consistent with the public calibration. XIS soft band temperatures obtained with the modification to the column density of the contaminant agree better with temperatures obtained with the EPIC-pn instrument of XMM-Newton, than with those derived using the Chandra-ACIS instrument. However, comparison of hard band fluxes obtained using Suzaku-XIS to fluxes obtained using the Chandra-ACIS and EPIC-pn instruments proved inconclusive.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。