Electroencephalogram (EEG) based brain-computer interfaces (BCI) may provide a means of communication for those affected by severe paralysis. However, the relatively low information transfer rates (ITR) of these systems, currently limited to 1 bit/sec, present a serious obstacle to their widespread adoption in both clinical and non-clinical applications. Here, we report on the development of a novel noninvasive BCI communication system that achieves ITRs that are severalfold higher than those previously reported with similar systems. Using only 8 EEG channels, 6 healthy subjects with little to no prior BCI experience selected characters from a virtual keyboard with sustained, error-free, online ITRs in excess of 3 bit/sec. By factoring in the time spent to notify the subjects of their selection, practical, error-free typing rates as high as 12.75 character/min were achieved, which allowed subjects to correctly type a 44-character sentence in less than 3.5 minutes. We hypothesize that ITRs can be further improved by optimizing the parameters of the interface, while practical typing rates can be significantly improved by shortening the selection notification time. These results provide compelling evidence that the ITR limit of noninvasive BCIs has not yet been reached and that further investigation into this matter is both justified and necessary.
Tiny noise, big mistakes: Adversarial perturbations induce errors in Brain-Computer Interface spellers
Huazhong University of Science and Technology(华中科技大学);University of Technology Sydney(悉尼科技大学);University of California San Diego(加州大学圣地亚哥分校);Zürich University of Applied Sciences(苏黎世应用科技大学)
On the utility of power spectral techniques with feature selection techniques for effective mental task classification in noninvasive BCI
Jawaharlal Nehru University(尼赫鲁大学);University of Essex(埃塞克斯大学);Imperial College London(伦敦帝国理工学院);Nantong University(南通大学);University of Technology Sydney(悉尼科技大学)
High Performance P300 Spellers Using GPT2 Word Prediction With Cross-Subject Training
University of Illinois at Urbana Champaign(伊利诺伊大学厄巴纳-香槟分校);University of Washington(华盛顿大学);UCLA(加州大学洛杉矶分校);PE Investments(PE投资公司);MIT(麻省理工学院);University of Texas, Southwestern, Dallas(德克萨斯大学西南医学中心)
Evaluation Of P300 Speller Performance Using Large Language Models Along With Cross-Subject Training
University of Illinois at Urbana Champaign(伊利诺伊大学厄巴纳-香槟分校);University of Washington(华盛顿大学);UCLA(加州大学洛杉矶分校);PE Investments(PE投资公司);MIT(麻省理工学院);University of Texas, Southwestern(德克萨斯大学西南医学中心)
Comparison of an open-hardware electroencephalography amplifier with medical grade device in brain-computer interface applications
脑机接口(Brain-computer interface,BCI)是一种很有前途的人机通信设备。基于非侵入性神经成像技术如脑电图(EEG)的脑机接口有许多应用,然而该技术的传播是有限的,部分原因是硬件的价格。在本文中,我们并排比较两个EEG放大器,消费级OpenBCI和医疗级g.tec g. USBamp。为此,我们采用了一个原始的蒙太奇,基于同一组电极的同时记录。进行了两组记录。在第一个实验中,使用了一个简单的适配器,在放大器和电极之间直接连接。然后,在第二个实验中,我们试图通过在适配器中添加“理想”二极管来消除一个放大器可能对另一个放大器造成的任何干扰。频谱和时间的功能进行了测试-前者与工作量监测任务,后者与视觉P300拼写任务。总体而言,结果表明OpenBCI板-或基于德州仪器ADS 1299芯片的类似解决方案-可能是传统EEG设备的有效替代品。尽管医疗级设备仍然优于OpenBCI,但后者给出了非常接近的EEG读数,从而在实践中实现了可能适合推广BCI使用的分类准确性。