用精密光掩模校正乳剂变形的新方法
A new method to correct deformations in emulsion using a precise photomask
摘要:
为了恢复核乳胶作为跟踪装置的高精度,提出了一种新的校正方法,主要是对显影过程中产生的乳胶变形进行校正。该方法基于精确的光掩模和对乳剂膜的仔细处理。在5 cm x 7 cm的面积上获得了0.6 μm的位置测量精度。该方法允许在具有少至10个用于对准的参考轨道的ECC块中以亚微米精度测量轨道段的位置。这样的性能对于地下实验室的混合乳液实验是重要的,在地下实验室中只有少量的用于对准的参考轨道可用。
英文摘要:
A new method to correct the emulsion deformation, mainly produced in the development process, is developed to recover the high accuracy of nuclear emulsion as a tracking device. The method is based on a precise photomask and a careful treatment of the emulsion films. A position measurement accuracy of 0.6 μm is obtained over an area of 5 cm x 7 cm. The method allows to measure positions of track segments with submicron accuracy in an ECC brick with as few as 10 reference tracks for alignment. Such a performance can be important for hybrid emulsion experiments at underground laboratories where only a small number of reference tracks for alignment are available.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。