用SLAO介质谐振器测量HTS薄膜的表面电阻
Surface resistance measurements of HTS thin films using SLAO dielectric resonator
摘要:
高温超导薄膜的表面电阻通常是使用封装在铜腔中的蓝宝石介质棒谐振器测量的。本文报道了用铝酸锶镧(SLAO)在18.2GHz谐振频率下测量YBa_2Cu_3O_(7-δ)薄膜表面电阻的方法。我们已经进行了误差分析的腔加载SLAO介质棒和验证测量使用两个蓝宝石(Al 2 O3)棒谐振器工作在谐振频率分别为24.6 GHz和10 GHz。对两组YBa_2Cu_3 O_(7-δ)薄膜的Rs值进行频率定标后,用SLAO和Sapphire激光器测量得到的Rs值吻合得很好。在同一腔体中使用相同尺寸的不同介质棒测量高温超导薄膜的Rs,可以在不同频率下对同一薄膜进行微波表征。
英文摘要:
Surface resistance of HTS films is typically measured using Sapphire dielectric rod resonators enclosed in a copper cavity. In this paper we present surface resistance measurements of YBa2Cu3O7-δ films using Strontium Lanthanum Aluminate (SLAO) at a resonant frequency of 18.2 GHz. We have performed the error analysis of the cavity loaded with SLAO dielectric rod and also verification measurements using two Sapphire (Al2O3) rod resonators operating at resonant frequencies of 24.6 GHz and 10 GHz respectively. Good agreement between the values of Rs of two sets of YBa2Cu3O7-δ films measured using the SLAO and the Sapphire dielectrics has been obtained after a frequency scaling of Rs was applied. Using different dielectric rods of the same size in the same cavity for measurements of Rs of HTS films, it is feasible to do microwave characterization of the same films at differing frequencies.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。