涵道对旋轴流通风机系统的设计与实验验证

Design and Experimental Validation of a Ducted Counter-rotating Axial-flow Fans System

Hussain Nouri, Florent Ravelet, Farid Bakir, Christophe Sarraf, Robert Rey

摘要:

对对旋式轴流通风机的设计进行了试验研究。风扇是用逆方法设计的。特别地,该系统被设计成具有纯轴向排出流。对旋风扇在管道流配置中操作,并且在标准化测试台架中测量总体性能。每个风扇的转速独立控制。风扇之间的相对轴向间距可以在17%至310%之间变化。结果表明,与传统转子或转子-定子级相比,效率大大提高。改变转速比的整体性能的影响进行了研究,并表明,该系统具有非常灵活的使用,与一个大补丁的高效率的工作点的参数空间。轴向间距的增加只会导致效率的小幅下降

英文摘要:

An experimental study on the design of counter-rotating axial-flow fans was carried out. The fans were designed using an inverse method. In particular, the system is designed to have a pure axial discharge flow. The counter-rotating fans operate in a ducted-flow configuration and the overall performances are measured in a normalized test bench. The rotation rate of each fan is independently controlled. The relative axial spacing between fans can vary from 17% to 310%. The results show that the efficiency is strongly increased compared to a conventional rotor or to a rotor-stator stage. The effects of varying the rotation rates ratio on the overall performances are studied and show that the system has a very flexible use, with a large patch of high efficient operating points in the parameter space. The increase of axial spacing causes only a small decrease of the efficiency