利用dE/dx截断平均测量μ子能量的改进方法
An improved method for measuring muon energy using the truncated mean of dE/dx
摘要:
μ子能量的测量对于大型切伦科夫探测器中的许多分析至关重要,特别是那些涉及从大气中微子背景中分离地外中微子的分析。传统上,通过测量沿着μ子路径的比能量损失(dE/dx)并将dE/dx与μ子能量相关联来确定μ子能量。由于高能μ子(E_mu > 1 TeV)随机损失能量,dE/dx值的分布相当大,导致IceCube探测器在1 km路径长度上观察到的μ子的典型能量分辨率为0.29 in log 10(E_mu)。在本文中,我们提出了一种改进的方法,使用截断平均和其他技术来确定μ子能量。μ子轨道被分成具有单独dE/dx值的单独段。消除具有最高dE/dx的片段导致与μ子能量更紧密相关的总体dE/dx。该方法的能量分辨率为0.22(log 10(E_mu)),提高了26%。该技术适用于任何大型水或冰探测器,并可能适用于大型闪烁体或液氩探测器。
英文摘要:
The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。