arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1206.0731astro-ph.COastro-ph.GAastro-ph.HEastro-ph.IM
收藏

17个透镜类星体宽线区的微透镜效应

Microlensing of the broad line region in 17 lensed quasars

D. Sluse, D. Hutsemékers, F. Courbin, G. Meylan, J. Wambsganss

摘要:

当强透镜类星体的图像被微透镜化时,由于相应发射区域的大小不同,其光谱的不同分量预计会被差分放大。预计将在连续谱中观察到色度变化,而发射线应根据它们所起源的区域的大小、几何形状和运动学而变形。到目前为止,仅在少数系统中报告了发射线的微透镜。本文研究了17个透镜类星体的成对像光谱的微透镜变形。该样品由13对以前未发表的光谱和4对来自文献的光谱组成。我们的分析是基于光谱分解技术,使我们能够独立的类星体发射线的详细建模的磁通量的微透镜部分隔离。使用这种技术,我们检测到85%的系统中的连续微透镜。其中,80%显示出宽发射线的微透镜效应。聚焦于我们光谱中最常见的谱线(CIII和MgII),我们检测到蓝色或红色机翼的微透镜,或者具有相同振幅的两个机翼的微透镜。这一观察结果意味着宽线区域一般不是球对称的。此外,频繁检测的蓝色和红色翅膀的微透镜独立,但不同时具有不同的幅度,不支持现有的微透镜模拟的双锥流出。我们的分析还提供了透镜图像之间的内在通量比和影响连续体的微透镜的大小。这两个量是特别相关的确定的物质在星系中的clusific形式的分数和检测的暗物质子结构通过识别的流量比异常。

英文摘要:

When an image of a strongly lensed quasar is microlensed, the different components of its spectrum are expected to be differentially magnified owing to the different sizes of the corresponding emitting region. Chromatic changes are expected to be observed in the continuum while the emission lines should be deformed as a function of the size, geometry and kinematics of the regions from which they originate. Microlensing of the emission lines has been reported only in a handful of systems so far. In this paper we search for microlensing deformations of the optical spectra of pairs of images in 17 lensed quasars. This sample is composed of 13 pairs of previously unpublished spectra and four pairs of spectra from literature. Our analysis is based on a spectral decomposition technique which allows us to isolate the microlensed fraction of the flux independently of a detailed modeling of the quasar emission lines. Using this technique, we detect microlensing of the continuum in 85% of the systems. Among them, 80% show microlensing of the broad emission lines. Focusing on the most common lines in our spectra (CIII] and MgII) we detect microlensing of either the blue or the red wing, or of both wings with the same amplitude. This observation implies that the broad line region is not in general spherically symmetric. In addition, the frequent detection of microlensing of the blue and red wings independently but not simultaneously with a different amplitude, does not support existing microlensing simulations of a biconical outflow. Our analysis also provides the intrinsic flux ratio between the lensed images and the magnitude of the microlensing affecting the continuum. These two quantities are particularly relevant for the determination of the fraction of matter in clumpy form in galaxies and for the detection of dark matter substructures via the identification of flux ratio anomalies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑