arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1205.4493astro-ph.CO
收藏

CfA4:94颗Ia型超新星的光变曲线

CfA4: Light Curves for 94 Type Ia Supernovae

Malcolm Hicken, Peter Challis, Robert P. Kirshner, Armin Rest, Claire E. Cramer, W. Michael Wood-Vasey, Gaspar Bakos, Perry Berlind, Warren R. Brown, Nelson Cal… 展开作者

Malcolm Hicken, Peter Challis, Robert P. Kirshner, Armin Rest, Claire E. Cramer, W. Michael Wood-Vasey, Gaspar Bakos, Perry Berlind, Warren R. Brown, Nelson Caldwell, Mike Calkins, Thayne Currie, Kathy de Kleer, Gil Esquerdo, Mark Everett, Emilio Falco, Jose Fernandez, Andrew S. Friedman, Ted Groner, Joel Hartman, Matthew J. Holman, Robert Hutchins, Sonia Keys, David Kipping, Dave Latham, George H. Marion, Gautham Narayan, Michael Pahre, Andras Pal, Wayne Peters, Gopakumar Perumpilly, Ben Ripman, Brigitta Sipocz, Andrew Szentgyorgyi, Sumin Tang, Manuel A. P. Torres, Amali Vaz, Scott Wolk, Andreas Zezas

摘要:

我们提出了2006年至2011年期间获得的94个光谱确认的Ia型超新星(SN Ia)在红移范围为0.0055至0.073的多波段光学光度测量。总共有5522个光变曲线点。我们表明,我们的自然系统SN测光的精度约为0.03等或更好的BVr 'i',0.06等的u ',和0.07等的点,亮度超过17.5等,并估计它有系统的不确定度为0.014,0.010,0.012,0.014,0.046,和0.073等的BVr' i 'u' U,分别我们的标准系统光度与公布的超新星Ia光变曲线和比较明星的比较显示,在~0.00-0.03马格范围内的样品之间的平均协议。我们讨论了我们的望远镜加检测器的直接单色照明克莱默等人(在准备)的吞吐量最近的测量。该技术在与SN测量相同的条件下测量通过望远镜、辅助光学器件、滤光片和探测器的整个光路。非常好的自然系统通带特性(包括波长和时间)是下一代超新星Ia测光达到0.01等精度水平的关键。现在低z Ia型超新星的样本足够大,可以从暗能量误差预算中消除大部分统计采样误差。但是,通过确定高精度探测器通带,结合光学和近红外(NIR)光度测量和光谱,使用附近的样品来阐明超新星Ia的人口特性,以及测量与哈勃流的局部偏差,来追求暗能量系统误差,将受益于更大的,仔细测量的附近样品。

英文摘要:

We present multi-band optical photometry of 94 spectroscopically-confirmed Type Ia supernovae (SN Ia) in the redshift range 0.0055 to 0.073, obtained between 2006 and 2011. There are a total of 5522 light curve points. We show that our natural system SN photometry has a precision of roughly 0.03 mag or better in BVr'i', 0.06 mag in u', and 0.07 mag in U for points brighter than 17.5 mag and estimate that it has a systematic uncertainty of 0.014, 0.010, 0.012, 0.014, 0.046, and 0.073 mag in BVr'i'u'U, respectively. Comparisons of our standard system photometry with published SN Ia light curves and comparison stars reveal mean agreement across samples in the range of ~0.00-0.03 mag. We discuss the recent measurements of our telescope-plus-detector throughput by direct monochromatic illumination by Cramer et al (in prep.). This technique measures the whole optical path through the telescope, auxiliary optics, filters, and detector under the same conditions used to make SN measurements. Extremely well-characterized natural-system passbands (both in wavelength and over time) are crucial for the next generation of SN Ia photometry to reach the 0.01 mag accuracy level. The current sample of low-z SN Ia is now sufficiently large to remove most of the statistical sampling error from the dark energy error budget. But pursuing the dark-energy systematic errors by determining highly-accurate detector passbands, combining optical and near-infrared (NIR) photometry and spectra, using the nearby sample to illuminate the population properties of SN Ia, and measuring the local departures from the Hubble flow will benefit from larger, carefully measured nearby samples.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑