XMM-牛顿上EPIC-pn相机的相对和绝对授时精度,来自蟹状星云和其他天体的X射线脉动
The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
摘要:
可靠的时间校准对于XMM-牛顿光变曲线与其他天文台的光变曲线进行准确比较至关重要,最终使用它们来获得精确的物理量。XMM-牛顿定时校准是基于脉冲星分析。然而,由于校准器同时显示定时噪声和毛刺,因此必须定期监测这些校准源。为此,XMM-牛顿天文台每年对蟹状星云脉冲星进行两次观测,以监测EPIC-pn相机在快速定时和突发模式下的绝对授时精度。我们提出了这一监测活动的结果,比较XMM牛顿数据从蟹状星云脉冲星(PSR B0531 + 21)与无线电测量。此外,我们还使用了5个周期从16 ms到197 ms的时钟(PSR J0537 - 69、PSR B0540 - 69、PSR B0833 - 45、PSR B1509 - 58和PSR B1055 - 52)来验证相对授时精度。我们分析了38 XMM牛顿观测(0.2 - 12.0千电子伏)的螃蟹采取了在第一个十年的任务和13个观测从五个互补的太阳能电池。所有数据均使用SAS(XMM-Newton Scientific Analysis Software,9.0版)进行处理。结合χ ^{2}检验的历元折叠技术用于推导相对授时精度。绝对授时精度是使用Crab数据并比较相位折叠光变曲线中的主X射线峰和射电峰之间的时间偏移来确定的。XMM-牛顿法的相对授时精度优于10 ^{-8}。最强的X射线脉冲峰值比相应的射电峰值早306 \pm 9 \mus,这与其他高能天文台如钱德拉、INTEGRAL和RXTE的结果一致。从我们的分析中得出的绝对授时精度是\pm 48 \mus。
英文摘要:
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with χ^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。