arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1109.6598astro-ph.SR
收藏

用EUNIS-07对SOHO/CDS和Hinode/EIS进行飞行下校准

Underflight calibration of SOHO/CDS and Hinode/EIS with EUNIS-07

Tongjiang Wang, Roger J. Thomas, Jeffrey W. Brosius, Peter R. Young, Douglas M. Rabin, Joseph M. Davila, Giulio Del Zanna

摘要:

2006年和2007年,戈达德太空飞行中心的极紫外正入射光谱仪(EUNIS)探空火箭的飞行为SOHO/CDS和Hinode/EIS提供了更新的辐射校准。EUNIS携带了两台独立的成像光谱仪,一阶覆盖300-370 A,二阶覆盖170-205 A。在每次飞行之后,在用于发射前校准CDS和EIS的同一设施中对火箭有效载荷进行端到端的辐射测量校准。在2007年的飞行中,EUNIS、SOHO CDS和Hinode EIS观测到了相同的太阳位置,这使得EUNIS的校准可以直接应用于CDS和EIS。用标准(版本4)响应度和标准长期校正校准的实测CDS NIS 1线强度由于响应度的降低而过低1.5倍。EIS校准更新以两种方式执行。一种是使用校准的EUNIS-07短波长(SW)通道的直接校准传输。另一种是使用不敏感线对,其中一个成员用EUNIS-07长波通道观测,另一个成员用EIS在长波或短波波段观测。从这两种方法的测量是在良好的协议,并确认(测量不确定性内)直接测量仪器的发射前的EIS响应度。测量结果还表明,EIS的响应度下降了约1.2的因素后,第一年的操作。EUNIS-07获得的EIS SW响应曲线的形状与发射前在实验室中测量的一致。EUNIS-07测量的宁静太阳He II 304 A强度的绝对值与CDS NIS测量的宁静区近盘中心的辐射亮度以及最近由CDS NIS和SDO/EVE获得的太阳最小辐照度一致。

英文摘要:

Flights of Goddard Space Flight Center's Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated radiometric calibrations for SOHO/CDS and Hinode/EIS. EUNIS carried two independent imaging spectrographs covering wavebands of 300-370 A in first order and 170-205 A in second order. After each flight, end-to-end radiometric calibrations of the rocket payload were carried out in the same facility used for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO CDS and Hinode EIS observed the same solar locations, allowing the EUNIS calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1 line intensities calibrated with the standard (version 4) responsivities with the standard long-term corrections are found to be too low by a factor of 1.5 due to the decrease in responsivity. The EIS calibration update is performed in two ways. One is using the direct calibration transfer of the calibrated EUNIS-07 short wavelength (SW) channel. The other is using the insensitive line pairs, in which one member was observed by EUNIS-07 long wavelength (LW) channel and the other by EIS in either LW or SW waveband. Measurements from both methods are in good agreement, and confirm (within the measurement uncertainties) the EIS responsivity measured directly before the instrument's launch. The measurements also suggest that the EIS responsivity decreased by a factor of about 1.2 after the first year of operation. The shape of the EIS SW response curve obtained by EUNIS-07 is consistent with the one measured in laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A intensity measured by EUNIS-07 is consistent with the radiance measured by CDS NIS in quiet regions near the disk center and the solar minimum irradiance obtained by CDS NIS and SDO/EVE recently.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑