arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1109.3228physics.atom-phphysics.optics
收藏

氦原子基态的XUV频率梳计量

XUV frequency comb metrology on the ground state of helium

Dominik Z. Kandula, Christoph Gohle, Tjeerd J. Pinkert, Wim Ubachs, Kjeld S. E. Eikema

摘要:

报道了基于近红外频率梳激光脉冲的成对放大和15次谐波非线性上转换的极紫外频率梳的工作原理。在对实验的第一次描述之后[Kandula等人,物理修订版信函105,063001(2010)],给出了对51 nm处的所得光谱是完全相位相干的并且可以应用于精密计量的证明的广泛回顾。该脉冲用于氦原子从基态到1 s4 p和1 s5 p 1P_1态的直接频率梳激发方案。通过辅助1064 nm脉冲的激光电离用于检测激发态群体,导致作为具有高达55%的调制对比度的频率梳的重复率的函数的类余弦信号。这种梳状结构的可见性的分析产生50阿秒的两个上变频梳状激光脉冲之间的估计定时抖动,这表明扩展到更短的波长应该是可行的。氦计量学研究结果表明,1 s4 p和1 s5 p 1P_1态的跃迁频率分别为5740806993(10)MHz和5814248672(6)MHz。这构成了XUV中的第一个绝对频率测量,在电磁波谱的无窗口部分达到了前所未有的精度。从测量的跃迁频率,八倍改进的4 He电离能的5945204212(6)MHz的推导。同时还发现~ 4 He基态兰姆位移的新值为41247(6)MHz。这个实验值与最近的理论计算结果一致,达到了mα^6和m^2/(Mα^5)的量级,但精度要高出6倍,从而为束缚双电子系统中的量子电动力学提供了一个严格的检验。

英文摘要:

The operation of a frequency comb at extreme ultraviolet (XUV) wavelengths based on pair-wise amplification and nonlinear upconversion to the 15th harmonic of pulses from a frequency comb laser in the near-infrared range is reported. Following a first account of the experiment [Kandula et al., Phys. Rev. Lett. 105, 063001 (2010)], an extensive review is given of the demonstration that the resulting spectrum at 51 nm is fully phase coherent and can be applied to precision metrology. The pulses are used in a scheme of direct-frequency-comb excitation of helium atoms from the ground state to the 1s4p and 1s5p 1P_1 states. Laser ionization by auxiliary 1064 nm pulses is used to detect the excited state population, resulting in a cosine-like signal as a function of the repetition rate of the frequency comb with a modulation contrast of up to 55%. Analysis of the visibility of this comb structure yields an estimated timing jitter between the two upconverted comb laser pulses of 50 attoseconds, whch indicates that extension to even shorter wavelengths should be feasible. The helium metrology investigation results in transition frequencies of 5740806993(10) MHz and 5814248672(6) MHz for excitation of the 1s4p and 1s5p 1P_1 states, respectively. This constitutes the first absolute frequency measurement in the XUV, attaining unprecedented accuracy in this windowless part of the electromagnetic spectrum. From the measured transition frequencies an eight-fold improved 4He ionization energy of 5945204212(6) MHz is derived. Also a new value for the 4He ground state Lamb shift is found of 41247(6) MHz. This experimental value is in agreement with recent theoretical calculations up to order mα^6 and m^2/(Mα^5), but with a six times higher precision, therewith providing a stringent test of quantum electrodynamics in bound two-electron systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑