arXiv 1108.0178cond-mat.mes-hall
收藏

避免单个NV缺陷的光学检测磁共振中的功率展宽以增强DC-磁场灵敏度

Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced DC-magnetic field sensitivity

A. Dréau, M. Lesik, L. Rondin, P. Spinicelli, O. Arcizet, J. -F. Roch, V. Jacques

摘要:

利用连续光探测电子自旋共振(ESR)谱,系统地研究了基于金刚石中单个氮空位(NV)缺陷的磁传感器的磁场灵敏度。我们首先研究了ESR对比度和线宽随微波和光泵浦功率的变化规律。实验结果与NV缺陷自旋动力学的简化模型非常一致,得到了约2 μT/ \sqrt{\rm Hz}的优化灵敏度。然后,我们证明了一个数量级的磁灵敏度的增强,通过使用一个简单的脉冲ESR方案。该技术基于用谐振微波π脉冲重复激发NV缺陷,随后是优化的读出激光脉冲,允许完全消除ESR线宽的功率展宽。所获得的灵敏度类似于通过使用拉姆齐型序列获得的灵敏度,这是用于检测DC磁场的最佳磁场灵敏度。

英文摘要:

We report a systematic study of the magnetic field sensitivity of a magnetic sensor based on a single Nitrogen-Vacancy (NV) defect in diamond, by using continuous optically detected electron spin resonance (ESR) spectroscopy. We first investigate the behavior of the ESR contrast and linewidth as a function of the microwave and optical pumping power. The experimental results are in good agreement with a simplified model of the NV defect spin dynamics, yielding to an optimized sensitivity around 2 μT/\sqrt{\rm Hz}. We then demonstrate an enhancement of the magnetic sensitivity by one order of magnitude by using a simple pulsed-ESR scheme. This technique is based on repetitive excitation of the NV defect with a resonant microwave π-pulse followed by an optimized read-out laser pulse, allowing to fully eliminate power broadening of the ESR linewidth. The achieved sensitivity is similar to the one obtained by using Ramsey-type sequences, which is the optimal magnetic field sensitivity for the detection of DC magnetic fields.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑