arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1107.5206physics.bio-phphysics.med-phq-bio.CB
收藏

声驱动生物芯片--流动对靶向药物载体细胞结合的影响

An acoustically-driven biochip - Impact of flow on the cell-association of targeted drug carriers

Christian Fillafer, Gerda Ratzinger, Jürgen Neumann, Zeno Guttenberg, Silke Dissauer, Irene Lichtscheidl, Michael Wirth, Franz Gabor, Matthias Schneider

摘要:

靶向药物载体与上皮和内皮屏障在体内的相互作用在很大程度上取决于体液的动力学。为了在结合测定中模拟这些条件,开发了完全生物相容的体外模型,其可以在拇指甲格式的细胞芯片上准确地模拟广泛的生理流动条件。该声学驱动微流控系统被用于研究蛋白质包被颗粒与细胞的相互作用特性。将聚(D,L-丙交酯-共-乙交酯)(PLGA)微粒(2.86 { \pm } 0.95 μm)与麦胚凝集素(WGA-MP,细胞粘附蛋白)或牛血清白蛋白(BSA-MP,非特异性蛋白)偶联,并在固定和流动条件下研究其与上皮细胞单层的结合。虽然在固定设置中分别检测到1500个{ \pm } 307 mm-2 WGA-MP和94个{ \pm } 64 mm-2 BSA-MP的平均数量与细胞结合,但在增加的流速下孵育越来越拮抗两种类型的表面改性颗粒的附着。然而,虽然BSA-MP的结合完全被流动抑制,但与WGA接枝导致明显的锚定效应。这通过在0.2 s-1和1 s-1的剪切速率下分别有747个{ \pm } 241 mm-2和104个{ \pm } 44 mm-2附着颗粒的平均数来表示。由于有利于并行化的流体芯片的紧凑性,该设置代表了一种非常有前途的方法,该方法朝向用于在生理流动条件下的药物递送载体的性能的筛选平台。在这方面,流动芯片预计将提供大量的信息,为成功的设计和开发有针对性的微米和纳米颗粒药物载体系统。

英文摘要:

The interaction of targeted drug carriers with epithelial and endothelial barriers in vivo is largely determined by the dynamics of the body fluids. To simulate these conditions in binding assays, a fully biocompatible in vitro model was developed which can accurately mimic a wide range of physiological flow conditions on a thumbnail-format cell-chip. This acoustically-driven microfluidic system was used to study the interaction characteristics of protein-coated particles with cells. Poly(D,L-lactide-co-glycolide) (PLGA) microparticles (2.86 {\pm} 0.95 μm) were conjugated with wheat germ agglutinin (WGA-MP, cytoadhesive protein) or bovine serum albumin (BSA-MP, nonspecific protein) and their binding to epithelial cell monolayers was investigated under stationary and flow conditions. While mean numbers of 1500 {\pm} 307 mm-2 WGA-MP and 94 {\pm} 64 mm-2 BSA-MP respectively were detected to be cell-bound in the stationary setup, incubation at increasing flow velocities increasingly antagonized the attachment of both types of surface-modified particles. However, while binding of BSA-MP was totally inhibited by flow, grafting with WGA resulted in a pronounced anchoring effect. This was indicated by a mean number of 747 {\pm} 241 mm-2 and 104 {\pm} 44 mm-2 attached particles at shear rates of 0.2 s-1 and 1 s-1 respectively. Due to the compactness of the fluidic chip which favours parallelization, this setup represents a highly promising approach towards a screening platform for the performance of drug delivery vehicles under physiological flow conditions. In this regard, the flow-chip is expected to provide substantial information for the successful design and development of targeted micro- and nanoparticulate drug carrier systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑