OSIRIS/GTC * 可调谐滤波器的波长校准

Wavelength calibration for OSIRIS/GTC* tunable filters

J. Mendez-Abreu, J. Sanchez Almeida, C. Munoz-Tunon, J. M. Rodriguez-Espinosa, J. A. L. Aguerri, D. Rosa Gonzalez, Y. D. Mayya, O. Vega, R. Terlevich, E. Terlev… 展开作者

J. Mendez-Abreu, J. Sanchez Almeida, C. Munoz-Tunon, J. M. Rodriguez-Espinosa, J. A. L. Aguerri, D. Rosa Gonzalez, Y. D. Mayya, O. Vega, R. Terlevich, E. Terlevich, E. Bertone, L. H. Rodriguez-Merino

摘要:

OSIRIS(成像和低分辨率集成光谱光学系统)是加那利大望远镜(GTC)的第一台光学仪器。它提供了一个灵活的和有竞争力的可调谐滤波器(TF)。由于它是基于工作在准直光束中的法布里-珀罗干涉仪,TF传输波长取决于目标相对于光轴的位置。这种影响是不可忽略的,必须在数据简化中加以考虑。我们的论文建立了一个波长校准OSIRIS TF的分光光度测量所需的精度,使用仪器的全视场(FOV)。通过$λ(R)=λ(0)/\sqrt{1+(R/f_2)^2}$很好地描述了FOV上的传输波长$λ(R)$的变化,其中$λ(0)$是中心波长,$R$表示距光轴的物理距离,并且$f_2=185.70\pm0.17\,$ mm是相机镜头的有效焦距。这种新的经验校准在整个OSIRIS FOV($\sim$ 8 \arcmin $\times$ 8 \arcmin)上产生优于1 μ m的精度,前提是光轴的位置在45 $μ$ m($\equiv$ 1.5合并像素)内已知。我们建议一个校准协议,授予这样的精度在很长一段时间内,重新调整OSIRIS光学,并在不同的波长范围。该校准不同于OSIRIS手册中的校准,尽管如此,OSIRIS手册为$R\lesssim 2\arcmin$提供了准确度$\lesssim1$校准。

英文摘要:

OSIRIS (Optical System for Imaging and low Resolution Integrated Spectroscopy) is the first light instrument of the Gran Telescopio Canarias (GTC). It provides a flexible and competitive tunable filter (TF). Since it is based on a Fabry-Perot interferometer working in collimated beam, the TF transmission wavelength depends on the position of the target with respect to the optical axis. This effect is non-negligible and must be accounted for in the data reduction. Our paper establishes a wavelength calibration for OSIRIS TF with the accuracy required for spectrophotometric measurements using the full field of view (FOV) of the instrument. The variation of the transmission wavelength $λ(R)$ across the FOV is well described by $λ(R)=λ(0)/\sqrt{1+(R/f_2)^2}$, where $λ(0)$ is the central wavelength, $R$ represents the physical distance from the optical axis, and $f_2=185.70\pm0.17\,$mm is the effective focal length of the camera lens. This new empirical calibration yields an accuracy better than 1\,Å across the entire OSIRIS FOV ($\sim$8\arcmin$\times$8\arcmin), provided that the position of the optical axis is known within 45 $μ$m ($\equiv$ 1.5 binned pixels). We suggest a calibration protocol to grant such precision over long periods, upon re-alignment of OSIRIS optics, and in different wavelength ranges. This calibration differs from the calibration in OSIRIS manual which, nonetheless, provides an accuracy $\lesssim1$Å\, for $R\lesssim 2\arcmin$.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑