arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1105.1954astro-ph.IM
收藏

优化TACTIC望远镜触发产生准则的模拟研究

Simulation studies for optimizing the trigger generation criteria for the TACTIC telescope

M. K. Koul, A. K. Tickoo, V. K. Dhar, K. Venugopal, K. Chanchalani, R. C. Rannot, K. K. Yadav, P. Chandra, M. Kothari, R. Koul

摘要:

本文介绍了TACTIC大气切伦科夫成像望远镜探测到的$γ$射线和宇宙线质子引起的大范围空气簇射的蒙特卡罗模拟结果,以优化其触发视场和拓扑触发产生方案。在不同的天顶距下进行了仿真研究。拓扑触发生成使用2或3个最近邻像素的重合来产生事件触发。这项研究的结果表明,11 $\times$ 11像素($\sim$ $3.4^o$ $\times$ $3.4^o$)的触发字段是相当理想的实现最大有效收集面积的$γ$ -射线从点源。关于拓扑触发产生的优化,它被发现,两个或三个最近的邻居像素产生几乎相似的结果,直到天顶距~ $25^o$与$\sim$ 1.5 TeV的阈值能量为$γ$射线。超过~ $25^o$的天顶距,结果表明,2像素的最近邻触发器应该是首选的。为了验证蒙特卡罗模拟的预测,特别是有效收集面积,还将模拟的积分率与相应的测量值进行了比较,从而可以可靠地确定源的能谱(或在未探测到的情况下的通量上限)。测得的触发率(根据$\sim$ 207小时的数据收集的望远镜在NN-2和NN-3触发配置)与模拟获得的相当好的匹配,再次保证了我们在估计阈值能量和检测率时遵循的程序是相当可靠的。

英文摘要:

In this paper, we present the results of Monte Carlo simulations of $γ$-ray and cosmic ray proton induced extensive air showers as detected by the TACTIC atmospheric Cherenkov imaging telescope for optimizing its trigger field of view and topological trigger generation scheme. The simulation study has been carried out at several zenith angles. The topological trigger generation uses a coincidence of 2 or 3 nearest neighbour pixels for producing an event trigger. The results of this study suggest that a trigger field of 11$\times$11 pixels ($\sim$ $3.4^o$ $\times$ $3.4^o$) is quite optimum for achieving maximum effective collection area for $γ$-rays from a point source. With regard to optimization of topological trigger generation, it is found that both 2 or 3 nearest neighbour pixels yield nearly similar results up to a zenith angle of ~$25^o$ with a threshold energy of $\sim$ 1.5 TeV for $γ$-rays. Beyond zenith angle of ~$25^o$, the results suggest that a 2-pixel nearest neighbour trigger should be preferred. Comparison of the simulated integral rates has also been made with corresponding measured values for validating the predictions of the Monte Carlo simulations, especially the effective collection area, so that energy spectra of sources (or flux upper limits in case of no detection) can be determined reliably. Reasonably good matching of the measured trigger rates (on the basis of $\sim$ 207 hours of data collected with the telescope in NN-2 and NN-3 trigger configurations) with that obtained from simulations reassures that the procedure followed by us in estimating the threshold energy and detection rates is quite reliable.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑