arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1103.4149astro-ph.CO
收藏

λ ~ 1 m源的积分偏振和新的旋转测度模糊度

Integrated Polarization of Sources at lambda ~1m and New Rotation Measure Ambiguities

Damon Farnsworth, Lawrence Rudnick, Shea Brown

摘要:

我们对来自韦斯特博克综合射电望远镜(WSRT)的六个观测点的致密射电源的偏振进行了分析,观测频率为350 MHz,覆盖率为35%。在用一个简单的分析模型对离轴仪器偏振进行校正后,只有少数585个强光源在这些波长处具有显著的偏振。最强源的1.4 GHz去极化率中值<0.2,这进一步证实了射电星系存在于磁化环境中的可能性,甚至在富星系团之外。选择了具有显著350 MHz极化的七个源进行更深入的法拉第结构分析。我们用去偏振屏和双组分模型拟合了Q/I和U/I作为λ ^[2]的函数的观测值。我们还进行了RM合成/清洁和偏振角与偏振角的标准拟合^[2]。我们发现,一个单一的旋转措施(RM),发现使用偏振角拟合或简单的屏幕模型,通常提供了一个穷人的配合时,解决方案被翻译回Q,U空间。因此,虽然使用这些技术可以找到一个单一的“特征”旋转测量,但可能无法充分表示源的法拉第结构。我们还表明,RM合成可能会产生一个错误的法拉第结构中存在的多个,干扰RM组件,即使当清洗的法拉第光谱进行。我们简要地探讨了旋转措施和法拉第结构的结果可以是可靠的条件下。文献中的许多测量不符合这些标准,我们讨论了这些如何影响所产生的科学结论,并提供了一个处方,以获得可靠的RM。

英文摘要:

We present an analysis of the polarization of compact radio sources from six pointings of the Westerbork Synthesis Radio Telescope (WSRT) at 350 MHz with 35% coverage in lambda^2. After correcting for the off-axis instrumental polarization with a simple analytical model, only a small number of 585 strong sources have significant polarizations at these wavelengths. The median depolarization ratio from 1.4 GHz for the strongest sources is <0.2, reinforcing the likelihood that radio galaxies are found in magnetized environments, even outside of rich clusters. Seven sources with significant 350 MHz polarization were selected for a more in-depth Faraday structure analysis. We fit the observed values Q/I and U/I as a function of lambda^2 using both a depolarizing screen and two component models. We also performed RM Synthesis/Clean and standard fitting of polarization angle vs. lambda^2. We find that a single rotation measure (RM), as found using polarization angle fitting or simple screen models, commonly provides a poor fit when the solutions are translated back into Q, U space. Thus, although a single "characteristic" rotation measure may be found using these techniques, the Faraday structure of the source may not be adequately represented. We also demonstrate that RM Synthesis may yield an erroneous Faraday structure in the presence of multiple, interfering RM components, even when cleaning of the Faraday spectrum is performed. We briefly explore the conditions under which rotation measures and Faraday structure results can be reliable. Many measurements in the literature do not meet these criteria; we discuss how these influence the resulting scientific conclusions and offer a prescription for obtaining reliable RMs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑