The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their increased stability and reliability. The experimental results on testing of such detectors with gaps between the electrodes of 1 and 3 mm are reported. It is demonstrated, that the best gas filling for the gas electron multipliers is neon with small admixture of quenching gases (for example, (N2+H2O) at ~100ppm). This filling offers the greatest coefficient of proportional multiplication as compared with other gases, at small electric potential difference between the GEM electrodes, in absence of streamer discharges in the proportional region. The results on operation of the multi-channel gas electron multiplier with wire cathode and continuous anode filled with Ne, Ar, Ar+CH4 and Ar+1%Xe are presented also. Based on the experimental observations, the explanation of the mechanism of formation of streamers is given.
A general solution to the positive ion feedback problem in Hybrid Photon Detectors (HPD), photo multipliers (PM) and other similar detectors was found in the insertion of a permanent electrostatic potential barrier which prevents drift of positive ions from the anode, or the first dynode, towards the photocathode. In this paper we present the method as applied to the Intevac HPD.
A proof of concept detector is presented for scintillation light detection in liquid argon using Silicon Photo-Multipliers. The aim of the work is to build an anti-Compton veto for germanium detectors operated directly in liquid argon like in the GERDA experiment. Properties of the Multi-Pixel Photon Counter (MPPC) are studied at cryogenic temperatures. To increase the light collection efficiency of the MPPCs wavelength shifting fibers were used. A veto efficiency comparable to a similar setup with a Photo-Multiplier Tube was achieved.
We study the performances of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation based on gas electron multipliers (GEMs) and operated in an avalanche mode in pure noble gases. The gas amplification in He, Ar and Kr is systematically studied at low temperatures, using triple-GEM multipliers. High gains, exceeding 10^4, were obtained in these gases in the range of 120-300 K. Stable electron avalanching was demonstrated in a saturated Kr vapor in the two-phase mode. These results are relevant for understanding basic mechanisms of electron avalanching at low temperatures …
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors were studied. Rather high gains, reaching 5000, and stable operation for several hours were observed in the two-phase Ar avalanche detector using a triple-GEM multiplier. The signals induced by X-rays, beta-particles and gamma-rays were successfully recorded. Preliminary results were obtained in the two-phase Xe avalanche detector: the maximum gain of the tri…
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for single photoelectrons and 0.5-1ns RMS for few-hundred photoelectrons per photon-pulse. Time resolution of about 10ns RMS was recorded for relativistic electrons from a 106Ru source.
We study the performance of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation, based on gas electron multipliers (GEMs). For the first time, high gas gains, exceeding 10^4, were obtained in pure He, Ar and Kr at low temperatures and the stable avalanche mode of operation was observed in the two-phase cryogenic detector in Kr. The electron avalanching at low temperatures, in the range of 120-300 K, is systematically studied.
The Thick Gas Electron Multiplier (THGEM) is a robust high-gain gas-avalanche electron multiplier - a building block of a variety of radiation detectors. It can be manufactured economically by standard printed-circuit drilling and etching technology. We present a detailed review of the THGEM and its derivatives. We focus on the physics phenomena that govern their operation and performances under different operation conditions. Technological aspects associated with the production of these detectors and their current and potential applications are discussed.
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MHSP and GEM multipliers at gains of about 1E+4, though at the expense of reduced effective gain in the first R- MHSP multiplier in the cascade.
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on independent of the rate. The gain uniformity across the GEM is improved. Coating opens the possibility to produce thick GEMs of very high gain.
Mechanisms of charging-up and charging-down of Gas Electron Multiplier (GEM) have been studied. Experimental investigations have been carried out on both dielectric polarization and radiation charging of GEMs. Environmental parameters, such as pressure and temperature have been monitored to normalize their effects on the charging-up and charging-down measurements. Variation in gain due to the combined, as well as individual, effects of the mentioned parameters has been illustrated.
Gas Electron Multiplication technology is finding more and more applications in beam instrumentation and at CERN these detectors have recently been adapted for use in transverse profile measurements at several of our facilities. In the experimental areas of CERN's Antiproton Decelerator, low energy Gas Electron Multipliers successfully replaced all Multwire Proportional Chambers in 2012 and another detector type has now been developed for high energy applications in the experimental areas of the SPS, totaling a potential of more than a hundred profile detectors to be replaced by GEM detectors …
We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs coupled to semi-transparent CsI photocathodes or reflective ones deposited on the THGEM surface were studied with Ar/CO2 (70:30), Ar/CH4 (95:5), CH4 and CF4. Gains of ~100000 or exceeding 1000000 were reached with single- or double-THGEM, respectively; the signals have 5-10 ns rise times. The electric field configurations at the THGEM electrodes result in an …
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne an…
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total gain of ~1.5*10^5 yielded ion back-flow fractions of 0.0015 and 0.0004, at drift fields of 0.5 and 0.1 kV/cm, respectively. A 2R-MHSP/MHSP cascaded multiplier operated at a total gain of ~10^5, yielded an…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEgIS beam lines. We…
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses in the few nanosecond rise-time scale were reached in single- and cascaded double-THGEM elements, in atmospheric-pressure standard gas mixtures with single photoelectrons. High single-electron detection efficiency is obtained in photon detectors combining THGEMs and semitransparent UV-sensitive CsI photocathodes or reflective ones deposited on the top THGEM …
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical profiles directly in one plane. This overcomes the problems previously encountered with multi-wire proportional chambers for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEGIS beam lines.…
We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded operation of two THGEMs is reported, with similar total gain but at lower voltages on each element. The present work encompasses a large variety of THGEM geometries and includes electric-field distribution calculations and electron transport simulations. We discuss the operation mechanism and some possible applications of THGEMs at low gas pressures.
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure, in all gases, in almost all the tested conditions; in Ar:Xe (95:5) similar gains were reached at pressures up to 2 bar. The energy resolution dependence on the gas, pressure, hole geometry and electri…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted leakage currents and spark breakdowns between the electrodes. Accidental spark events in such MGEM don't lead to their failure as far as positive ions quickly move away from the breakdown region by a strong electric field in the gap region. In this work, we present a review of such GEMs. The chambers containing MGEMs (WGEMs) with pin-anodes are proposed as det…
We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences applied between the various electrodes provide an efficient collection of ionization electrons within the MM-THGEM holes and a large charge avalanche multiplication between the meshes. Different from conventional hole-type multipliers (e.g. Gas Electron Multipliers - GEMs, Thick Gas Electron Multipliers - THGEMs, etc.), which are characterized by a variable (dip…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 $μ$m in the pad-row direction and 313 $μ$m in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.
TIGER (Turin Integrated Gem Electronics for Readout) is a mixed-mode front-end ASIC developed to readout the new inner tracking detector of the BESIII experiment, carried out at BEPCII in Beijing. The detector is planned to be installed during the 2018 upgrade and features an innovative three-layer triple-CGEM (Cylindrical Gas Electron Multiplier) with analog readout. The ASIC comprises 64 channels, each of which features a dual-branch architecture to extract and digitize the timestamp and charge of the input signal. The time-of-arrival is provided by a set of low-power TDCs, based on analog i…
A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace UVsensitive wire chambers for single-photon recording in Cherenkov and other detectors. Other hole-multipliers with patterned electrodes (Micro-Hole and Strip Plates) and improved ion-blocking properties are discussed; these permit reducing considerably photon- and ion-induced secondary effects. Photon detectors with other electron-multiplier techniques are bri…
In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a comparative study of these configurations along with the single GEM results observed in our previous work has been reported. The increase in gain due to polarization of GEM foil dielectric and reduction in gain due to charge accumulation on dielectric are studied for various field configurations and different radiation intensities.
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emitted from a photocathode on the electrode's surface, are collected into the holes; after crossing the liquid-gas interface, they induce electroluminescence within the bubble. After having validated in …
The bubble-assisted Liquid Hole Multiplier (LHM) is a recently-proposed concept for the combined detection of ionization electrons and primary scintillation photons in noble-liquid time projection chambers. The LHM comprises a perforated micro-pattern electrode (e.g. Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM) immersed in the liquid, with a bubble of the noble gas supported underneath. Ionization electrons and scintillation-induced photoelectrons extracted from a cesium iodide photocathode drift through the electrode's holes and induce electroluminescence (EL) sign…
The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it consists of a densely perforated assembly of multiple insulating substrate sheets (e.g., FR-4), sandwiched between thin metallic-electrode layers. The electron avalanche processes occur along the successive multiplication stages within the M-THGEM holes, under the action of strong dipole fields resulting from the application of suitable potential differences…
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multiplier. Higher gains, of about 5000, have been attained in two-phase Ar CRADs with a hybrid triple-stage multiplier, comprising of a double-THGEM followed by a GEM. The performance of two-phase CRADs in …
A method is proposed to dump the spurious signals induced by fluorescence of the electrodes in gaseous detectors under strong X-Ray irradiation, introducing a special fluorescence suppressor electrode between the sensitive and the amplifying parts of the detector.
We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respectively. In Ar, the gain varies very little with pressure, being 3000-9000; in Ne the maximum attainable gain, about 100000, is pressure independent above 2 bar. The results are compared with that of sin…
The performance of thick GEMs (THGEMs) was compared to that of thin GEMs in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare-event experiments. The detectors comprised a 1 cm thick liquid-Ar layer followed by either a double-THGEM or a triple-GEM multiplier, operated in the saturated vapor above the liquid phase. Three types of THGEMs were studied: those made of G10 and Kevlar and that with resistive electrodes (RETHGEM). Only the G10-made THGEM showed a stable performance in two-phase Ar with…
For the first time secondary scintillation, generated within the holes of a thick gas electron multiplier (TGEM) immersed in liquid argon, has been observed and measured using a silicon photomultiplier device (SiPM). 250 electron-ion pairs, generated in liquid argon via the interaction of a 5.9KeV Fe-55 gamma source, were drifted under the influence of a 2.5KV/cm field towards a 1.5mm thickness TGEM, the local field sufficiently high to generate secondary scintillation light within the liquid as the charge traversed the central region of the TGEM hole. The resulting VUV light was incident on a…
A novel concept is proposed for large-volume single-phase noble-liquid TPC detectors for rare events. Both radiation-induced scintillation-light and ionization-charge are detected by Liquid Hole-Multipliers, LHM, immersed in the noble liquid. The latter may consist of cascaded Gas Electron Multipliers (GEM), Thick Gas Electron Multiplier (THGEM) electrodes or others, coated with CsI UV-photocathodes. Electrons, photo-induced on CsI by primary scintillation in the noble liquid, and event-correlated drifting ionization electrons are amplified in the cascaded elements primarily through electrolum…
A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to ionize gas inside the drift field two types of voltage supplier circuits were fabricated, and array of 2x4 pads of each size 4x8 mm^2 were utilized for collecting avalanche charges. Preliminary testing results show that the circuit which produces high voltage and low current is better than that of low voltage and high current supplier circuit in terms of x-ray si…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with holes and electrodes on both sides. GEMs made by radiation-hard dielectrics or wide band-gap semiconductors are desirable for some applications. The results of the first tests of the gas electron multiplier made of radiation-hard materials, such as polycrystalline CVD diamond with a thickness of 100 microns is described. Here we report on fabrication of GEM b…
We present the design and characterization of TIGER (Turin Integrated Gem Electronics for Readout), a 64-channel ASIC developed for the readout of the CGEM (Cylindrical Gas Electron Multiplier) detector, the proposed inner tracker for the 2018 upgrade of the BESIII experiment, carried out at BEPCII in Beijing. Each ASIC channel features a charge sensitive amplifier coupled to a dual-branch shaper stage, optimized for timing and charge measurement, followed by a mixed-mode back-end that extracts and digitizes the timestamp and charge of the input signals. The time-of-arrival is provided by a se…
Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders, accelerators, astrophysics, neutrino and rare-event physics involving scintillators are using SiPMs as photodetectors. They are gradually substituting PMTs in many applications, especially where low voltages are required and high magnetic field is present. Hamamatsu Photonics K.K., one of leading producers of photo-detectors, in the last year introduced the S14160 s…
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y s…
A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system. The thick ionization gap makes the THGEM chamber a mini-drift chamber. This kind mini-drift THGEM chamber is proposed as part of a transition radiation detector (TRD) for identifying electrons at an Electron Ion Collider (EIC) experiment. Through this cosmic ray test, an efficiency larger than 94$\%$ and a spatial resolution $\sim$220 $μ$m are achieved for t…
THick Gas Electron Multipliers (THGEMs) are robust and high gain Micro Pattern Gaseous Detectors which are economically manufactured by standard drilling and etching of thin printed circuit boards. In this paper, we present our recent simulation as well as experimental studies on THGEMs which have been fabricated in India using local expertise. Two types of THGEMs have been fabricated; one set has holes without any external rim and another set has holes with rims. These detectors have been characterized using argon-carbon dioxide and argon-isobutane gas mixtures. Electron transmission, effecti…
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continue via electron-avalanche propagation. The photon-mediated stage allows, by a proper choice of geometry and fields, complete blocking of the ion back-flow into the first element; thus, only ions from the…
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the first time bubbles were optically observed in LAr; their properties were studied in contact with different material surfaces. This permitted investigating the bubble-electrodynamics via numerical simul…
The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and 1.5 mm steps between them. The gap between the electrodes is equal to 3 mm, while the total working area has a diameter of 20 mm. The neon gas fillings of the MWGEM chamber with micro admixtures of N_2 and H_2O have been tested. The total maximal coefficient of proportional multiplication of electrons in neon with admixture of (H_2O+N_2)<100 ppm of 30000 is o…
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization …
The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from glass with large U-Th content. We propose to use advanced Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann Institute of Science (WIS). These "hole-multipliers" will measure …
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV muons at CERN-SPS. Signals induced through the resistive plate on anode readout strips were recorded with APV25/SRS electronics. The experimental results are compared with that of Monte Carlo simulat…
Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in a CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show that the CsI photocathode deposited in the InGrid mesh does not alter the device performance. Maximum gains of ~6000 were reached in a single-grid element operated in Ar/CH4, with a 2% Ion Back Flow …
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in a single- and in two-electrode cascade, respectively. The signal rise time is of a few ns and the counting-rate capability approaches 10 MHz/mm^2 at 10^4 gains. Sub-mm localization precision was demonst…
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of adjustable charge amplification, a promising readout technology for next-generation neutrino detectors and direct Dark Matter searches. In this paper, we report on the first operation of a LAr LEM-TPC prototype - with an active area of 10$\times$10 cm$^2$ and 21 cm drift length - equipped with a single 1 mm thick LEM amplifying stage and a t…
A method to set the predefined PMT gain with high precision is described. The method supposes minimal participation of the operator. After the rough initial setting of the gain, the automated system adjusts the PMT gain within a predefined precision (up to 2%). The method has been successfully applied at the Borexino PMT test facility at LNGS for the gain adjustment of the 2000 photomultipliers for the Borexino detector
Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work, position resolution, charge spread, energy resolution and gain uniformity have been investigated experimentally for single and double GEM geometries using an Fe-55 source. The position resolution measurements have been performed by a novel method, using a high precision instrument for source movement and is found to be highly successful. The result shows that t…
A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are presented.
We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. We measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk…
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, inducing electroluminescence within the bubble. The resulting photons are detected with a Hamamatsu VUV4 quad-SiPM array - providing the deposited energy with a charge-only RMS resolution of 6.6%. The image…
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at ave…