arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1005.1074astro-ph.CO
收藏

Herschel PEP:1.5<z<2.5大质量星系的恒星形成率

Herschel PEP: The star-formation rates of 1.5<z<2.5 massive galaxies

R. Nordon, D. Lutz, L. Shao, B. Magnelli, S. Berta, B. Altieri, P. Andreani, H. Aussel, A. Bongiovanni, A. Cava, J. Cepa, A. Cimatti, E. Daddi, H. Dominguez, D.… 展开作者

R. Nordon, D. Lutz, L. Shao, B. Magnelli, S. Berta, B. Altieri, P. Andreani, H. Aussel, A. Bongiovanni, A. Cava, J. Cepa, A. Cimatti, E. Daddi, H. Dominguez, D. Elbaz, N. M. Forster Schreiber, R. Genzel, A. Grazian, G. Magdis, R. Maiolino, A. M. Perez Garcia, A. Poglitsch, P. Popesso, F. Pozzi, L. Riguccini, G. Rodighiero, A. Saintonge, M. Sanchez-Portal, P. Santini, E. Sturm, L. Tacconi, I. Valtchanov, M. Wetzstein, E. Wieprecht

摘要:

恒星形成率(SFR)是研究星系演化的一个重要参数。在z~2处SFR测量的准确性由于观测和理论模型之间的不一致而受到质疑。后者预测的SFR在这个红移,通常是一个因素4或更低的测量。我们提出了恒星形成率的基础上的热量测量的远红外(FIR)光度的大质量1.5<z<2.5,正常的恒星形成星系(SFG),这不依赖于消光校正和/或光谱能量分布的外推。这些测量是基于GOODS-N中的观测,使用赫歇尔机载的光电探测器阵列相机和光谱仪(PACS),作为PACS进化探测器(PEP)项目的一部分,首次解决了FIR波长下这些红移的单个SFG。我们比较了基于FIR的SFR与更常用的24微米和UV SFR。我们发现,仅来自24微米的SFR比真实SFR高约4-7.5倍。这种高估取决于光度:当log L(24 μ m)>12.2 L_sun时逐渐增加。SFG和AGN倾向于表现出相同的24微米过剩。UV SFR与基于FIR的SFR更接近。使用Calzetti UV消光校正导致FIR SFR的平均过量高达0.3 dex和0.35 dex的散射。因此,以前的紫外SFR得到证实,平均过剩,而缩小差距,是不足以解释观测到的SFR和模拟预测之间的差异。

英文摘要:

The star formation rate (SFR) is a key parameter in the study of galaxy evolution. The accuracy of SFR measurements at z~2 has been questioned following a disagreement between observations and theoretical models. The latter predict SFRs at this redshift that are typically a factor 4 or more lower than the measurements. We present star-formation rates based on calorimetric measurements of the far-infrared (FIR) luminosities for massive 1.5<z<2.5, normal star-forming galaxies (SFGs), which do not depend on extinction corrections and/or extrapolations of spectral energy distributions. The measurements are based on observations in GOODS-N with the Photodetector Array Camera & Spectrometer (PACS) onboard Herschel, as part of the PACS Evolutionary Probe (PEP) project, that resolve for the first time individual SFGs at these redshifts at FIR wavelengths. We compare FIR-based SFRs to the more commonly used 24 micron and UV SFRs. We find that SFRs from 24 micron alone are higher by a factor of ~4-7.5 than the true SFRs. This overestimation depends on luminosity: gradually increasing for log L(24um)>12.2 L_sun. The SFGs and AGNs tend to exhibit the same 24 micron excess. The UV SFRs are in closer agreement with the FIR-based SFRs. Using a Calzetti UV extinction correction results in a mean excess of up to 0.3 dex and a scatter of 0.35 dex from the FIR SFRs. The previous UV SFRs are thus confirmed and the mean excess, while narrowing the gap, is insufficient to explain the discrepancy between the observed SFRs and simulation predictions.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑