arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1003.5922quant-ph
收藏

回音壁模式光学微谐振腔光力学

Cavity optomechanics with whispering-gallery-mode optical micro-resonators

Albert Schliesser, Tobias J. Kippenberg

摘要:

光学和机械自由度的参数耦合形成了许多力和机械位移的超灵敏测量的基础。具有机械柔性边界的光学腔增强了光机械相互作用,但也产生了定性的新耦合动力学。早在1967年,在一项开创性的工作中,V. Braginsky从理论上分析了辐射压力在干涉测量过程中的作用,但几十年来一直没有进行实验探索。在这里,我们使用回音壁模式(WGM)光学微谐振器来研究这些辐射压力现象。光学微谐振器同时托管光学和机械模式,其被系统地分析和优化以具有超低机械耗散、超过机械振荡周期的光子存储时间(即“解析边带制度”)和大的光机械耦合。它表明,动态反作用可以用来冷却机械模式,即,以减少它们的热激发随机运动。利用这种新的技术与低温预冷却的机械振荡器,声子占据的机械径向呼吸模式可以减少到约60个激发量子。相应的位移波动用干涉测量法监测,灵敏度为10^-18 m/Hz^(1/2),低于标准量子极限(SQL)的不精确度。它示出,这里采用的光学测量技术操作在一个接近理想的方式根据量子测量的原则,显示反作用不精确的产品接近量子极限。展望了晶体WGM谐振器的光机实验和“光机诱导透明”效应(类似于电磁诱导透明)。

英文摘要:

Parametric coupling of optical and mechanical degrees of freedom forms the basis of many ultra-sensitive measurements of both force and mechanical displacement. An optical cavity with a mechanically compliant boundary enhances the optomechanical interaction, but also gives rise to qualitatively new coupled dynamics. As early as 1967, in a pioneering work, V. Braginsky analyzed theoretically the role of radiation pressure in the interferometric measurement process, but it has remained experimentally unexplored for many decades. Here, we use whispering-gallery-mode (WGM) optical microresonators to study these radiation pressure phenomena. Optical microresonators simultaneously host optical and mechanical modes, which are systematically analyzed and optimized to feature ultra-low mechanical dissipation, photon storage times exceeding the mechanical oscillation period (i.e. the "resolved-sideband regime") and large optomechanical coupling. It is demonstrated that dynamical backaction can be employed to cool mechanical modes, i.e., to reduce their thermally excited random motion. Utilizing this novel technique together with cryogenic pre-cooling of the mechanical oscillator, the phonon occupation of mechanical radial-breathing modes could be reduced to about 60 excitation quanta. The corresponding displacement fluctuations are monitored interferometrically with a sensitivity at the level of 10^-18 m/Hz^(1/2), which is below the imprecision at the standard quantum limit (SQL). It is shown that optical measurement techniques employed here are operating in a near-ideal manner according to the principles of quantum measurement, displaying a backaction-imprecision product close to the quantum limit. An outlook on optomechanical experiments with crystalline WGM resonators and the effect of "optomechanically induced transparency" (analogous to electromagnetically induced transparency) is given.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑