arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 0911.4504astro-ph.CO
收藏

XMM -{ \em Newton}和FUSE沿PKS视线的WHIM细丝的初步证据~0558-504

XMM-{\em Newton} and FUSE Tentative Evidence for a WHIM filament along the Line of Sight to PKS~0558-504

F. Nicastro, Y. Krongold, D. Fields, M. L. Conciatore, L. Zappacosta, M. Elvis, S. Mathur, I. Papadakis

摘要:

我们提出了一个可能的OVIII X射线吸收线在$z=0.117 \pm 0.001$,如果得到证实,将是第一个与广泛的HI Ly $β$(BLB:FWHM= $160^{+50}_{-30}$ km s $^{-1}$)吸收。这个吸收体沿着视线指向附近的($z=0.1372$)塞弗特1星系PKS~0558-504,与WHIM灯丝一致。在PKS~0558-504的两个独立的XMM-牛顿光谱(长的$\sim 600$ ks来宾观察值和较短的$\sim 300$ ks总校准观察值)中检测到X射线吸收剂,合并的单线统计显著性为2.8 $σ$(两个光谱中分别为2.7 $σ$和1.2 $σ$)。当与我们的自洽混合光电离WHIM模型拟合时,组合的XMM-{ \em Newton}光谱与OVIII K $α$在$z=(0.117 \pm 0.001)$处的存在一致。该模型给出了最佳拟合温度和吸附剂的等效H柱密度$T=6.56_{-0.17}^{+0.19}$ K和logN $_H=(21.5 \pm 0.3) (Z/Z_{0.01\odot})^{-1}$ cm $^{-2}$。通过在PKS~0558-504的档案FUSE光谱中检测到宽的和复杂的HI Ly $β$吸收,增加了该单个X射线检测的统计显著性,其红移$z=0.1183 \pm 0.0001$与X射线吸收体的最佳拟合红移一致。该细胞系的单线统计学显著性为4.1 PDMATHAMT(如果考虑系统学,则为3.7 PDMATHAMT),因此检测的合并(HI+OVIII)统计学显著性为5.0 PDMATHAMT。在这个热吸收系统中,在一致的红移处检测到金属和H线,使我们能够推测它的金属丰度。通过将X射线吸收体的体积与在$z_{BLB}=0.1183 \pm 0.0001$的FUSE光谱中检测到的BLB线相关联,我们获得了1-4太阳的金属丰度。

英文摘要:

We present a possible OVIII X-ray absorption line at $z=0.117 \pm 0.001$ which, if confirmed, will be the first one associated with a broad HI Ly$β$ (BLB: FWHM=$160^{+50}_{-30}$ km s$^{-1}$) absorber. The absorber lies along the line of sight to the nearby ($z=0.1372$) Seyfert 1 galaxy PKS~0558-504, consistent with being a WHIM filament. The X-ray absorber is marginally detected in two independent XMM-Newton spectra of PKS~0558-504, a long $\sim 600$ ks Guest-Observer observation and a shorter, $\sim 300$ ks total, calibration observation, with a combined single line statistical significance of 2.8$σ$ (2.7$σ$ and 1.2$σ$ in the two spectra, respectively). When fitted with our self-consistent hybrid-photoionization WHIM models, the combined XMM-{\em Newton} spectrum is consistent with the presence of OVIII K$α$ at $z=(0.117 \pm 0.001)$. This model gives best fitting temperature and equivalent H column density of the absorber of log$T=6.56_{-0.17}^{+0.19}$ K, and logN$_H=(21.5 \pm 0.3) (Z/Z_{0.01\odot})^{-1}$ cm$^{-2}$. The statistical sigificance of this single X-ray detection is increased by the detection of broad and complex HI Ly$β$ absorption in archival FUSE spectra of PKS~0558-504, at redshifts $z=0.1183 \pm 0.0001$ consistent with the best-fitting redshift of the X-ray absorber. The single line statistical significance of this line is 4.1$σ$ (3.7$σ$ if systematics are considered), and thus the combined (HI+OVIII) statistical significance of the detection is of 5.0$σ$. The detection of both metal and H lines at a consistent redshift, in this hot absorbing system, allows us to speculate on its metallicity. By associating the bulk of the X-ray absorber with the BLB line detected in the FUSE spectrum at $z_{BLB}=0.1183 \pm 0.0001$, we obtain a metallicity of 1-4\% Solar.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑