arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0909.5081physics.atom-ph
收藏

极薄盒中~(85)Rb和~(87)Rb在D1激发下的非线性磁光共振

Nonlinear magneto-optical resonances at D1 excitation of 85Rb and 87Rb in an extremely thin cell

M. Auzinsh, R. Ferber, F. Gahbauer, A. Jarmola, L. Kalvans, A. Papoyan, D. Sarkisyan

摘要:

在超薄盒(ETC)中测量了天然同位素组成的原子蒸气中铷原子D1跃迁的非线性磁光共振。所有的超精细跃迁的同位素已被研究了广泛的激光功率密度,激光失谐,ETC壁分离。当基态总角动量F_g大于或等于激发态总角动量F_e时,在激光诱导荧光(LIF)中观察到了预期的暗共振。与普通细胞的情况不同,ETC中形成的暗共振的宽度和对比度显著依赖于激光与原子跃迁的失谐。基于光学布洛赫方程的理论模型被用来计算谐振曲线的形状。该模型平均了不同原子速度群的贡献,考虑了所有相邻的超精细跃迁,考虑了外部磁场中磁子能级的分裂和混合,并包括对激光辐射相干特性的详细处理。这种理论方法已经成功地描述了普通汽泡中的非线性磁光共振现象。虽然ETC中的某些模型参数的值与普通细胞的情况显著不同,但相同的物理过程被用于对两种情况进行建模。然而,为了描述ETC中的共振,必须根据ETC的独特特征修改关键参数,例如过境弛豫率和多普勒宽度。ETC的测量和计算的共振曲线之间的协议是令人满意的,虽然不如在普通电池的情况下。

英文摘要:

Nonlinear magneto-optical resonances have been measured in an extremely thin cell (ETC) for the D1 transition of rubidium in an atomic vapor of natural isotopic composition. All hyperfine transitions of both isotopes have been studied for a wide range of laser power densities, laser detunings, and ETC wall separations. Dark resonances in the laser induced fluorescence (LIF) were observed as expected when the ground state total angular momentum F_g was greater than or equal to the excited state total angular momentum F_e. Unlike the case of ordinary cells, the width and contrast of dark resonances formed in the ETC dramatically depended on the detuning of the laser from the exact atomic transition. A theoretical model based on the optical Bloch equations was applied to calculate the shapes of the resonance curves. The model averaged over the contributions from different atomic velocity groups, considered all neighboring hyperfine transitions, took into account the splitting and mixing of magnetic sublevels in an external magnetic field, and included a detailed treatment of the coherence properties of the laser radiation. Such a theoretical approach had successfully described nonlinear magneto-optical resonances in ordinary vapor cells. Although the values of certain model parameters in the ETC differed significantly from the case of ordinary cells, the same physical processes were used to model both cases. However, to describe the resonances in the ETC, key parameters such as the transit relaxation rate and Doppler width had to be modified in accordance with the ETC's unique features. Agreement between the measured and calculated resonance curves was satisfactory for the ETC, though not as good as in the case of ordinary cells.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑