We developed an instrument design capable of measuring linear X-ray polarization over a broad-band using conventional spectroscopic optics. A set of multilayer-coated flats reflects the dispersed X-rays to the instrument detectors. The intensity variation with position angle is measured to determine three Stokes parameters: I, Q, and U -- all as a function of energy. By laterally grading the multilayer optics and matching the dispersion of the gratings, one may take advantage of high multilayer reflectivities and achieve modulation factors > 50% over the entire 0.2 to 0.8 keV band. This instrument could be used in a small orbiting mission or scaled up for the International X-ray Observatory. Laboratory work has begun that would demonstrate the capabilities of key components.
X-ray polarimetry is still largely uncharted territory. With the upcoming launch of IXPE, we will learn a lot more about X-ray polarization at energies above 2 keV, but so far no current or accepted mission provides observational capabilities below 2 keV. We present ray-tracing results for a small orbital mission that could be launched within NASA's Pioneer or SmallSat cost-cap to provide X-ray polarimetry below 2 keV. The design is based on the use of laterally-graded multi-layer (ML) mirrors, a concept that we have developed theoretically for the REDSoX Polarimeter, for which most components…
EFOSC2 (the European Southern Observatory Faint Object Spectrograph and Camera v2) is one of the workhorse instruments on ESO's New Technology Telescope (NTT), and is one of the most popular instruments at La Silla observatory. It is mounted at a Nasmyth focus, and therefore exhibits strong, wavelength and pointing-direction dependent instrumental polarisation. In this document we describe our efforts to calibrate the broadband imaging polarimetry mode, and provide a calibration for broadband B, V, R filters to a level that satisfies most use cases (i.e. polarimetric calibration uncertainty ~0…
We present continued development of laterally graded multilayer mirrors (LGMLs) for a telescope design capable of measuring linear X-ray polarization over a broad spectral band. The multilayer-coated mirrors are used as Bragg reflectors at the Brewster angle. By matching to the dispersion of a spectrometer, one may take advantage of high multilayer reflectivities and achieve modulation factors over 50% over the entire 0.2-0.8 keV band. In Phase II of the polarimetry beam-line development, we demonstrated that the system provides 100% polarized X-rays at 0.525 keV (Marshall et al. 2013). Here, …
Regular large-scale polarimetric observations in Crimean astrophysical observatory began in the early 1960s. In 2002 - 2017 the single-channel aperture photometer-polarimeter with a quarter-wave plate at the 2.6-m Shajn mirror telescope (SMT) was used. We accumulated a large homogeneous data set of polarimetric observations of different types of objects that are to be published separately. Correct polarimetric data processing requires high polarization standards and zero-polarization stars. We aim to improve the data reduction and calibration process to obtain further results with highest poss…
Hard X / soft gamma-ray polarimetric analysis can be performed efficiently by the study of Compton scattering anisotropy in a detector composed of fine pixels. But in the energy range above 100 keV where sources flux are extremely weak and instrumental background very strong, such delicate measurement is actually very difficult to perform. Laue lens is an emerging technology based on diffraction in crystals allowing the concentration of soft gamma rays. This kind of optics can be applied to realize an efficient high-sensitivity and high-angular resolution telescope, at the cost of a field of v…
We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-…
The maturity of current detectors based on technologies that range from solid state to gases renewed the interest for X-ray polarimetry, raising the enthusiasm of a wide scientific community to improve the performance of polarimeters as well as to produce more detailed theoretical predictions. We will introduce the basic concepts about measuring the polarization of photons, especially in the X-rays, and we will review the current state of the art of polarimeters in a wide energy range from soft~to hard X-rays, from solar flares to distant astrophysical sources. We will introduce relevant examp…
In this chapter we present a brief summary of methods, instruments and calibration techniques used in modern astronomical polarimetry in the optical wavelengths. We describe the properties of various polarization devices and detectors used for optical broadband, imaging and spectropolarimetry, and discuss their advantages and disadvantages. The necessity of a proper calibration of the raw polarization data is emphasized and methods of the determination and subtraction of instrumental polarization are considered. We also present a few examples of high-precision measurements of optical polarizat…
We investigate the structure of the O-type binary system HD 48099 by measuring linear polarization that arises due to light scattering process. Linear polarization measurements of HD 48099 in the B, V and R passbands with the high-precision Dipol-2 polarimeter have been carried out. The data have been obtained with the 60 cm KVA (Observatory Roque de los Muchachos, La Palma, Spain) and T60 (Haleakala, Hawaii, USA) remotely controlled telescopes during 31 observing nights. Polarimetry in the optical wavelengths has been complemented by observations in the X-rays with the SWIFT space observatory…
The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The polarisation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is s…
PolPy: A universal tool for X-ray/gamma-ray polarimetry using common data format standards
Raman Research Institute(拉曼研究所);NASA Goddard Space Flight Center(美国国家航空航天局戈达德太空飞行中心);University of Geneva(日内瓦大学);Indian Institute of Technology Bombay(孟买印度理工学院);INAF Istituto di Astrofisica e Planetologia Spaziali(意大利国家天体物理研究所空间与行星物理学所);University of New Hampshire(新罕布什尔大学)
The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detection of soft x-ray polarisation after 40 years from the Crab nebula and pulsar with PolarLight, a miniature polarimeter utilising a novel technique onboard a CubeSat. The polarisation fraction of the C…
Over the past few decades impressive progress has been made in the field of photon polarimetry, especially in the hard X-ray and soft gamma-ray energy regime. Measurements of the linear degree of polarization for some of the most energetic astrophysical sources, such as Gamma Ray Bursts (GRBs) or Blazars, is now possible, at energies below the pair creation threshold. As such, a new window has been opened into understanding exact nature of the non-thermal emission mechanisms responsible for some of the most energetic phenomena in the Universe. There are still many open questions, and active de…
A Large-Area Optical Time Projection Chamber for Hard X-ray Polarimetry with Directional Imaging of Low-Energy Electron Recoils
Gran Sasso Science Institute(格兰萨索科学研究所);INFN Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所大萨索国家实验室);INFN Laboratori Nazionali di Frascati(意大利国家核物理研究所弗拉斯卡蒂国家实验室);IAPS - INAF Istituto di Astrofisica e Planetologia Spaziali(空间天体物理学和行星学研究所-意大利国家天体物理研究所)
Context: Polarimetry is a very powerful tool to uncover various properties of astronomical objects that remain otherwise hidden in standard imaging or spectroscopic observations. However, the reliable measurement of the low polarization signal from astronomical sources requires a good control of spurious instrumental polarization induced by the various components of the optical system and the detector. Aims: We perform a detailed multi-wavelength calibration study of the FORS2 instrument at the VLT operating in imaging polarimetric mode (IPOL) to characterize the spatial instrumental polarizat…
In the magnetar model, the quiescent non-thermal soft X-ray emission from Anomalous X-ray Pulsars and Soft-Gamma Repeaters is thought to arise from resonant comptonization of thermal photons by charges moving in a twisted magnetosphere. Robust inference of physical quantities from observations is difficult, because the process depends strongly on geometry and current understanding of the magnetosphere is not very deep. The polarization of soft X-ray photons is an independent source of information, and its magnetospheric imprint remains only partially explored. In this paper we calculate how re…
Since the birth of X-ray Astronomy, spectacular advances have been seen in the imaging, spectroscopic and timing studies of the hot and violent X-ray Universe, and further leaps forward are expected in the future. On the other hand, polarimetry is very much lagging behind: after the measurements of the Crab Nebula and Scorpius X-1, obtained by OSO-8 in the 70s, no more observations have been performed in the classical X-ray band, even if some interesting results have been obtained in hard X-rays and in soft gamma-rays. The NASA/ASI mission IXPE, scheduled for the launch in 2021, is going to pr…
DragonflyPol: Wide-Field Optical Linear Polarimetry with the Dragonfly Telephoto Array (Instrument Description and Commissioning)
University of South Carolina(南卡罗来纳大学);Stanford University(斯坦福大学);Chiba Institute of Technology(千叶工业大学);Hiroshima University(广岛大学);Kyung Hee University(庆熙大学);NRC Herzberg Astronomy & Astrophysics Research Centre(加拿大国家研究委员会赫茨伯格天文学与天体物理学研究中心);University of Toronto(多伦多大学)
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm$^{2}$sr high throughput optical system that had two ambient temperature mirrors and four anti-reflection coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. P…
Spectroscopy focusing array (SFA) and Polarimetry focusing array (PFA) are the two major payloads of enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-\RNum{1} X-ray mirror module is implemented in SFA and PFA to achive high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray beam is a prerequisite to ensure the accuracy of the results. Hence, to assist the alignment of the X-ray mirror module, an X-ray focal plane detector is designed based on the back-illuminated scienti…
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical process. This is why most of the projects for the next generation of space missions covering the tens of keV to the MeV region require a polarization …