在测力计上运动期间异戊二烯和丙酮浓度分布

Isoprene and acetone concentration profiles during exercise on an ergometer

J. King, A. Kupferthaler, K. Unterkofler, H. Koc, S. Teschl, G. Teschl, W. Miekisch, J. Schubert, H. Hinterhuber, A. Amann

摘要:

一个实时记录设置相结合的呼气VOC测量质子转移反应质谱(PTR-MS)与血液动力学和呼吸数据。基于测量的呼吸流量实现呼出气的连续自动采样:流量控制快门机制确保只有潮气末呼气段被吸入质谱仪进行分析。获得了两种原型化合物(异戊二烯和丙酮)在几种运动方案中的呼气浓度曲线,重申并补充了Senthilmohan等人[1]和Karl等人[2]报告的关于这些化合物动态反应的早期实验结果。由于异戊二烯的亲脂性和低亨利常数,异戊二烯对肺通气和灌注的变化反应非常敏感,而亲水性丙酮表现出相当稳定的行为。呼气异戊二烯浓度和摩尔流量的特征(中值)值,即,每分钟呼出异戊二烯量分别为100 ppb和29 nmol/min,具有一些个体内的逐日变化。在运动开始时,呼吸异戊二烯浓度急剧增加,通常在约1分钟内增加约3-4倍。由于通气量的同时增加,摩尔流量的相关增加甚至更加明显,导致峰值摩尔流量与静息时摩尔流量之间的比率约为11。我们的设置具有很大的潜力,在捕捉非极性,低溶性挥发性有机化合物在广泛的测量范围内的连续动态与影响呼气动力学的决定性生理因素的同时评估。

英文摘要:

A real-time recording setup combining exhaled breath VOC measurements by proton transfer reaction mass spectrometry (PTR-MS) with hemodynamic and respiratory data is presented. Continuous automatic sampling of exhaled breath is implemented on the basis of measured respiratory flow: a flow-controlled shutter mechanism guarantees that only end-tidal exhalation segments are drawn into the mass spectrometer for analysis. Exhaled breath concentration profiles of two prototypic compounds, isoprene and acetone, during several exercise regimes were acquired, reaffirming and complementing earlier experimental findings regarding the dynamic response of these compounds reported by Senthilmohan et al. [1] and Karl et al. [2]. While isoprene tends to react very sensitively to changes in pulmonary ventilation and perfusion due to its lipophilic behavior and low Henry constant, hydrophilic acetone shows a rather stable behavior. Characteristic (median) values for breath isoprene concentration and molar flow, i.e., the amount of isoprene exhaled per minute are 100 ppb and 29 nmol/min, respectively, with some intra-individual day-to-day variation. At the onset of exercise breath isoprene concentration increases drastically, usually by a factor of ~3-4 within about one minute. Due to a simultaneous increase in ventilation, the associated rise in molar flow is even more pronounced, leading to a ratio between peak molar flow and molar flow at rest of ~11. Our setup holds great potential in capturing continuous dynamics of non-polar, low-soluble VOCs over a wide measurement range with simultaneous appraisal of decisive physiological factors affecting exhalation kinetics.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑